Serial ATA III Features
1.3
Serial ATA III Features
The SATA bus is a high-speed, internal bus that provides a low pin count (LPC), low
voltage level bus for device connections between a host controller and a SATA device.
The following list describes the SATA III features of the RAID controllers:
Supports SATA III data transfers of 6Gb/s
Supports STP data transfers of 6Gb/s
Provides a serial, point-to-point storage interface
Simplifies cabling between devices
Eliminates the master-slave construction used in parallel ATA
Allows addressing of multiple SATA II targets through an expander
Allows multiple initiators to address a single target (in a fail-over configuration)
through an expander
1.4
Solid State Drive Features
The MegaRAID firmware supports the use of SSDs as standard drives and/or additional
controller cache, referred to as CacheCade 2.0 SSD Read Caching software. SSD drives
are expected to behave like SATA or SAS HDDs except for the following:
High random read speed (because there is no read-write head to move)
High performance-to-power ratio, as these drives have very low power
consumption compared to HDDs
Low latency
High mechanical reliability
Lower weight and size
NOTE: Support for SATA SSD drives applies only to those drives that support ATA-8 ACS
compliance.
You can choose whether to allow a virtual drive to consist of both CacheCade 2.0 SSD
Read Caching software devices and HDDs. For a virtual drive that consists of CacheCade
2.0 SSD Read Caching software only, you can choose whether to allow SAS CacheCade
2.0 SSD Read Caching software drives and SATA CacheCade 2.0 SSD Read Caching
software drives in that virtual drive. For virtual drives that have both CacheCade 2.0 SSD
Read Caching software and HDDs, you can choose whether to mix SAS and SATA HDD
drives with SAS and SATA CacheCade 2.0 SSD Read Caching software devices in various
combinations.l
NOTE: Support for SATA SDD drives applies only to those drives that support ATA-8 ACS
compliance.
- MegaRAID SAS 9240-4i MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SafeStore Software MegaRAID SAS 9361-4i MegaRAID SAS 9361-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID CacheCade Pro 2.0 Software MegaRAID SAS 9341-4i MegaRAID SAS 9341-8i MegaRAID SAS 9380-8e MegaRAID SAS 9380-4i4e