9 delete virtual drives with ssd caching, 6 software license key – Avago Technologies MegaRAID Fast Path Software User Manual
Page 226

Page 226
LSI Corporation Confidential
|
July 2011
MegaRAID SAS Software User Guide
Chapter 5: MegaRAID Command Tool
|
Software License Key
5.5.9
Delete Virtual Drives with SSD
Caching
Use the command in the following table to delete one or all virtual drives that have SSD
caching enabled.
5.5.10
Clear Configurations on
CacheCade Pro 2.0 Virtual Drives
Use the command in the following table if the selected controller has any CacheCade
Pro 2.0 virtual drives or if any data exists in the cache and you want to clear all existing
configurations on a controller.
5.5.11
Create a CacheCade Pro 2.0
Virtual Drive with RAID level and Write
Policy
Use the command in the following table to create a CacheCade Pro 2.0 virtual drive
with RAID level and Write Policy settings.
5.6
Software License Key
Use the commands in this section to obtain a software license key to enable the
advanced features present in the controller.
Table 34: Delete Virtual Drives with SSD Caching
Convention
MegaCLI -CfgLdDel -LX|-L0,2,5...|-LALL [-Force]
-aN|-a0,1,2|-aALL
Description
Deletes virtual drives associated with a CacheCade virtual drive, with a write
policy, using the Force option.
[-Force]
Specifies that the data is not flushed before deleting the virtual drive.
Table 35: Clear Configurations on CacheCade Pro 2.0 Virtual Drives
Convention
MegaCLI -cfgclr [-force] -a0
Description
Clears all existing configurations on a controller if the controller has any
CacheCade 2.0 virtual drives or if any data exists in the cache.
[-Force] Specifies that the data is not flushed before deleting the virtual drive.
Table 36: Create a CacheCade Pro 2.0 Virtual Drive with RAID level and Write Policy
Convention
MegaCLI -CfgCacheCadeAdd [-rX] -Physdrv[E0:S0,...]
{-Name LdNamestring} [WT|WB|ForcedWB] [-assign
-LX|L0,2,5..|LALL] -aN|-a0,1,2|-aALL
Description
-Physdrv[E0:S0,...]
: Specifies the physical drive enclosure and the
slots to use to construct a drive group.
-Name LdNamestring
: This is the name given to the CacheCade software
cache drive.
[-rX]
: Specifies the RAID level.
[WT|WB|ForcedWB]:
Specifies the write policy- WT (Write Through, WB
(Write Back), ForcedWB (Forced Write Back). While creating a CacheCade
virtual drive, if you specify the ForcedWB parameter, even if the CacheCade
virtual drive goes into a degraded mode, the write policy stays as Write Back.
[-assign]
: Specifies that the virtual drive can be associated with a
CacheCade virtual drive.
Table 37: Software License Key
Convention
MegaCli ELF –GetSafeId –a0
Description
Displays the Safe ID of the controller.
Convention
MegaCli ELF -ControllerFeatures -aN|-a0,1,2|-aALL
- MegaRAID SAS 9240-4i MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SafeStore Software MegaRAID SAS 9361-4i MegaRAID SAS 9361-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID CacheCade Pro 2.0 Software MegaRAID SAS 9341-4i MegaRAID SAS 9341-8i MegaRAID SAS 9380-8e MegaRAID SAS 9380-4i4e