Avago Technologies MegaRAID Fast Path Software User Manual
Page 484

Page 484
LSI Corporation Confidential
|
July 2011
MegaRAID SAS Software User Guide
Appendix A: Events and Messages
|
Event Messages
0x0166
Critical
Snapshot space for %s in snapshot repository %s, is full
0x0167
Warning
View at %s to snapshot at %s, is 80%% full on snapshot
repository %s
0x0168
Critical
View at %s to snapshot at %s, is full on snapshot repository %s
0x0169
Critical
Snapshot repository lost for %s
0x016a
Warning
Snaphot repository restored for %s
0x016b
Critical
Snapshot encountered an unexpected internal error: 0x%lx
0x016c
Information
Auto Snapshot enabled on %s (snapshot repository %s)
0x016d
Information
Auto Snapshot disabled on %s (snapshot repository %s)
0x016e
Critical
Configuration command could not be committed to disk,
please retry
0x016f
Information
COD on %s updated as it was stale
0x0170
Warning
Power state change failed on %s (from %s to %s)
0x0171
Warning
%s is not available
0x0172
Information
%s is available
0x0173
Information
%s is used for CacheCade with capacity 0x%lx logical blocks
0x0174
Information
%s is using CacheCade %s
0x0175
Information
%s is no longer using CacheCade %s
0x0176
Critical
Snapshot deleted due to resource constraints for %s in
snapshot repository %s
0x0177
Warning
Auto Snapshot failed for %s in snapshot repository %s
0x0178
Warning
Controller reset on-board expander
0x0179
Warning
CacheCade (%s) capacity changed and is now 0x%lx logical
blocks
0x017a
Warning
Battery cannot initiate transparent learn cycles
0x017b
Information
Premium feature %s key was applied for - %s
0x017c
Information
Snapshot schedule properties changed on %s
0x017d
Information
Snapshot scheduled action is due on %s
0x017e
Information
Performance Metrics: collection command 0x%lx
0x017f
Information
Premium feature %s key was transferred - %s
0x0180
Information
Premium feature serial number %s
0x0181
Warning
Premium feature serial number mismatched. Key-vault serial
num - %s
0x0182
Warning
Battery cannot support data retention for more than %d
hours. Please replace the battery
0x0183
Information
%s power policy changed to %s (from %s)
0x0184
Warning
%s cannot transition to max power savings
0x0185
Information
Host driver is loaded and operational
0x0186
Information
%s mirror broken
0x0187
Information
%s mirror joined
Table 150: Event Messages (Continued)
Number
Severity Level
Event Text
- MegaRAID SAS 9240-4i MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SafeStore Software MegaRAID SAS 9361-4i MegaRAID SAS 9361-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID CacheCade Pro 2.0 Software MegaRAID SAS 9341-4i MegaRAID SAS 9341-8i MegaRAID SAS 9380-8e MegaRAID SAS 9380-4i4e