Avago Technologies MegaRAID Fast Path Software User Manual
Page 445
LSI Corporation Confidential
|
July 2011
Page 445
MegaRAID SAS Software User Guide
Chapter 11: Using MegaRAID Advanced Software
|
CacheCade Advanced Software
Figure 310: Create CacheCade - SSD Caching - Summary
This screen displays the drive group name, the RAID level, the number of drives, the
total capacity, the free capacity, the CacheCade virtual drive name, the capacity being
used, and the write policy.
11. Click Finish.
A confirmation message displays after the CacheCade virtual drive is successfully
created. The CacheCade drive icon appears next to the RAID controller in the left frame
in the MegaRAID Storage Manager window.
11.4.2.1 Modifying the
CacheCade Virtual Drive Properties
You can modify the name and the write policy of a CacheCade virtual drive any time
after a CacheCade virtual drive is created. Perform the following steps to change the
virtual drive properties:
1. Right-click on a controller in the device tree in the left frame of the MegaRAID
Storage Manager window and select Set Virtual Drive Properties.
OR
Select a controller and select Go To>>Virtual Drive>>Set Virtual Drive Properties.
The Set Virtual Drive Properties dialog appears, as shown in the following figure.
- MegaRAID SAS 9240-4i MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SafeStore Software MegaRAID SAS 9361-4i MegaRAID SAS 9361-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID CacheCade Pro 2.0 Software MegaRAID SAS 9341-4i MegaRAID SAS 9341-8i MegaRAID SAS 9380-8e MegaRAID SAS 9380-4i4e