9 display the free space, 14 virtual drive-related options, 1 display virtual drive information – Avago Technologies MegaRAID Fast Path Software User Manual
Page 248

Page 248
LSI Corporation Confidential
|
July 2011
MegaRAID SAS Software User Guide
Chapter 5: MegaRAID Command Tool
|
Virtual Drive-Related Options
5.13.9
Display the Free Space
Use the command in the following table to display the free space that is available to use
for configuration on the selected controllers.
5.14
Virtual Drive-Related
Options
You can use the commands in this section to select settings for the virtual drives and
perform actions on them.
5.14.1
Display Virtual Drive
Information
Use the command in the following table to display virtual drive information for the
selected controllers.
5.14.2
Change the Virtual Drive Cache
and Access Parameters
Use the command in the following table to change the cache policy and access policy
for the virtual drives on the selected controllers.
Table 81: Display Free Space
Convention
MegaCli –CfgFreeSpaceInfo -aN|-a0,1,2|-aALL
Description
Displays all of the free space available for configuration on the selected
controllers. The information displayed includes the number of drive groups,
the number of spans in each drive group, the number of free space slots in
each drive group, the start block, and the size (in both blocks and
megabytes) of each free space slot.
Table 82: Display Virtual Drive Information
Convention
MegaCli –LDInfo –Lx|-L0,1,2|-Lall -aN|-a0,1,2|-aALL
Description
Displays information about the virtual drives on the selected controllers.
This information includes the name, RAID level, RAID level qualifier, capacity
in megabytes, state, stripe size, number of drives, span depth, cache policy,
access policy, and ongoing activity progress, if any, including initialization,
background initialization, consistency check, and reconstruction.
Table 83: Change Virtual Drive Cache and Access Parameters
Convention
MegaCli –LDSetProp WT | WB [-Immediate]| RA |NORA |
ADRA|-Cached|Direct|CachedBadBBU|NoCachedBadBBU} |
-RW|RO|Blocked | {-Name nameString} |
-EnDskCache|DisDskCache –Lx| -L0,1,2|-Lall
-aN|-a0,1,2|-aALL
Description
Allows you to change the following virtual drive parameters:
-WT
(Write through), WB (Write back): Selects write policy.
-Immediate
: Indicates that the changes take place immediately.
-NORA
(No read ahead), RA (Read ahead), ADRA (Adaptive read ahead):
Selects read policy.
-Cached
, -Direct: Selects cache policy.
-CachedBadBBU|NoCachedBadBBU
: Specifies whether to use write
cache when the BBU is bad.
-RW
, -RO, Blocked: Selects access policy.
-EnDskCache
: Enables drive cache.
-DisDskCache
: Disables drive cache.
- MegaRAID SAS 9240-4i MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SafeStore Software MegaRAID SAS 9361-4i MegaRAID SAS 9361-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID CacheCade Pro 2.0 Software MegaRAID SAS 9341-4i MegaRAID SAS 9341-8i MegaRAID SAS 9380-8e MegaRAID SAS 9380-4i4e