3 command line abbreviations and conventions, 1 abbreviations used in the command line, 2 conventions – Avago Technologies MegaRAID Fast Path Software User Manual
Page 219
LSI Corporation Confidential
|
July 2011
Page 219
MegaRAID SAS Software User Guide
Chapter 5: MegaRAID Command Tool
|
Command Line Abbreviations and Conventions
For the Novell NetWare operating system, LSI provides an executable file,
MegaCLI.nlm
, that you can execute from any folder. No installation is required. The
output of all of the commands appears in the console window.
5.3
Command Line
Abbreviations and Conventions
This section explains the abbreviations and conventions used with MegaCLI
Configuration Utility commands.
5.3.1
Abbreviations Used in the
Command Line
The following table lists the abbreviations for the virtual drive parameters used in the
following sections.
5.3.2
Conventions
You can specify multiple values for some options. You can enter commands for a single
controller (–aN), multiple controllers (-a0,1,2) or work on all present controllers
(-aALL). The options are denoted as –aN|-a0,1,2|-aALL in this document and
specify that you can enter commands for one controller, multiple controllers, or all
controllers.
NOTE: All options in the MegaRAID Command Tool are position-dependent, unless
otherwise specified.
The following table describes the conventions used in the options.
Table 24: Command Line Abbreviations
Abbreviation
Description
WB
Write Back write policy
WT
Write Through write policy
ADRA
Adaptive Read Ahead read policy
RA
Read Ahead read policy
NORA
Normal Read policy (No read ahead)
DIO
Direct I/O cache policy
CIO
Cached I/O cache policy
Table 25: Conventions
Convention
Description
|
Specifies “or,” meaning you can choose between options.
-aN
N
specifies the controller number for the command.
-a0,1,2
Specifies the command is for controllers 0, 1, and 2. You can select two or
more controllers in this manner.
-aALL
Specifies the command is for all controllers.
-Lx
x
specifies the virtual drive number for the command.
-L0,1,2
Specifies the command is for virtual drives 0, 1, and 2. You can select two or
more virtual drives in this manner.
-Lall
Specifies the command is for all virtual drives.
- MegaRAID SAS 9240-4i MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SafeStore Software MegaRAID SAS 9361-4i MegaRAID SAS 9361-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID CacheCade Pro 2.0 Software MegaRAID SAS 9341-4i MegaRAID SAS 9341-8i MegaRAID SAS 9380-8e MegaRAID SAS 9380-4i4e