2 starting a learn cycle manually – Avago Technologies MegaRAID Fast Path Software User Manual

Page 393

background image

LSI Corporation Confidential

|

July 2011

Page 393

MegaRAID SAS Software User Guide

Chapter 9: Monitoring Controllers and Its Attached Devices

|

Battery Learn Cycle

Figure 260: Set Learn Cycle Properties

4. Select one of the two automatic learn cycles:

— Select the Enable radio button to enable an automatic learn cycle.

— Select the Disable radio button to disable an automatic learn cycle.

5. You can delay the start of the next learn cycle up to 7 days (168 hours) by specifying

the hours in the Delay scheduled learn cycle by field.

6. Select the Remind me when to start a learn cycle check box to receive a reminder

to start a manual learn cycle.

NOTE: After selecting Disable, if you select Enable, the controller firmware resets the
battery module properties to initiate an immediate battery learn cycle. The Next Learn
cycle
field (in

Figure 258

or

Figure 259

) will not be updated until the battery relearn is

completed. Once the relearning cycle is completed, the value in the Next Learn cycle
field will display the new date and the time of the next battery learning cycle.

9.20.2

Starting a Learn Cycle

Manually

To start the learn cycle properties manually, perform the following steps:

1. Click the Physical tab to open the Physical view.

2. Select the BBU icon in the left panel.

3. Select Go To->BBU->Start Learn Cycle.

Another way to start the learn cycle is to right-click the BBU icon and select Start Learn
Cycle