Avago Technologies MegaRAID Fast Path Software User Manual
Page 233

LSI Corporation Confidential
|
July 2011
Page 233
MegaRAID SAS Software User Guide
Chapter 5: MegaRAID Command Tool
|
Controller Property-Related Options
Table 51: Set Controller Properties
Convention
MegaCli –AdpSetProp {CacheFlushInterval –val}|{RebuildRate -val}| {PatrolReadRate
–val}|{BgiRate –val}|{CCRate –val}| {ReconRate –val}| {SpinupDriveCount
–val}|{SpinupDelay –val}|{CoercionMode –val} | {ClusterEnable
–val}|{PredFailPollInterval –val}| {BatWarnDsbl –val}| {EccBucketSize
–val}|{EccBucketLeakRate –val}|{AbortCCOnError –val}|AlarmEnbl | AlarmDsbl |
AlarmSilence |{SMARTCpyBkEnbl –val} |
-AutoDetectBackPlaneDsbl | -CopyBackDsbl | -LoadBalanceMode
| NCQEnbl | NCQDsbl | {SSDSMARTCpyBkEnbl -val} | {MaintainPdFailHistoryEnbl -val} |
{EnblSpinDownUnConfigDrvs -val} | AutoEnhancedImportEnbl | AutoEnhancedImportDsbl |
{-UseFDEOnlyEncrypt -val} | {-PrCorrectUncfgdAreas -val} | -aN| -a0,1,2|-aALL
Description
Sets the properties on the selected controllers. The possible settings are:
CacheFlushInterval
: Cache flush interval in seconds. Values: 0 to 255.
RebuildRate
: Rebuild rate. Values: 0 to 100.
PatrolReadRate
: Patrol read rate. Values: 0 to 100.
BgiRate
: Background initialization rate. Values: 0 to 100.
CCRate
: Consistency check rate. Values: 0 to 100.
ReconRate
: Reconstruction rate. Values: 0 to 100.
SpinupDriveCount
: Maximum number of drives to spin up at one time. Values: 0 to 255.
SpinupDelay
: Number of seconds to delay among spinup groups. Values: 0 to 255.
CoercionMode
: Drive capacity Coercion mode. Values: 0 - None, 1 - 128 MB, 2 - 1 GB.
ClusterEnable
: Cluster is enabled or disabled. Values: 0 - Disabled, 1 - Enabled.
PredFailPollInterval
: Number of seconds between predicted fail polls. Values: 0 to 65535.
BatWarnDsbl
: Disable warnings for missing battery or missing hardware. Values: 0 - Enabled, 1 - Disabled.
EccBucketSize
: Size of ECC single-bit-error bucket. Values: 0 to 255.
EccBucketLeakRate
: Leak rate (in minutes) of ECC single-bit-error bucket. Values: 0 to 65535.
AbortCCOnError
: If firmware detects inconsistency, then CC is aborted.
AlarmEnbl
: Set alarm to enabled.
AlarmDsbl
: Set alarm to disabled.
AlarmSilence
: Silence an active alarm.
SMARTCpyBkEnbl
: Enable copyback operation on SMART errors. Copyback is initiated when the first SMART error occurs on
a drive that is part of a virtual drive.
AutoDetectBackPlaneDsbl
: Detect automatically if the backplane has been disabled.
CopyBackDsbl
: Disable or enable the copyback operation.
LoadBalanceMode
: Disable or enable the load balancing mode.
NCQEnbl
: Enable the native command queueing.
NCQDsbl
: Disable the native command queueing.
SSDSMARTCpyBkEnbl
: Enable copyback operation on Self-Monitoring Analysis and Reporting Technology (SMART) errors
on a CacheCade software. Copyback is initiated when the first SMART error occurs on a SSD that is part of a virtual drive.
MaintainPdFailHistoryEnbl
: Enable maintenance of the history of a failed drive.
EnblSpinDownUnConfigDrvs
: Enable spindown of unconfigured drives.
AutoEnhancedImportEnbl
: Enable the automatic enhanced import of foreign drives.
AutoEnhancedImportDsbl
: Disable the automatic enhanced import of foreign drives.
UseFDEOnlyEncrypt
: Use encryption on FDE drives only.
PrCorrectUncfgdAreas
:
- MegaRAID SAS 9240-4i MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SafeStore Software MegaRAID SAS 9361-4i MegaRAID SAS 9361-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID CacheCade Pro 2.0 Software MegaRAID SAS 9341-4i MegaRAID SAS 9341-8i MegaRAID SAS 9380-8e MegaRAID SAS 9380-4i4e