Chapter 5: MegaRAID Command Tool

|

SAS Topology

5.17.2

Flash the Firmware in Mode 0

with the ROM File

Use the command in the following table to flash the firmware in Mode 0 with the ROM
file specified at the command line for the selected controllers. This command is only
supported for MS-DOS.

5.18

SAS Topology

The commands in this section are used to display SAS topology.

Use the command in the following table to display the PHY connection information for
physical PHY M on the selected controllers. Each PHY can form one side of the physical
link in a connection with a PHY on a different device. The physical link contains four
wires that form two differential signal pairs. One differential pair transmits signals, and
the other differential pair receives signals. Both differential pairs operate
simultaneously and allow concurrent data transmission in both the receive and the
transmit directions. PHYs are contained within ports.

A port can contain a single PHY or can contain multiple PHYs. A narrow port contains a
single PHY, and a wide port contains multiple PHYs.

5.19

Diagnostic-Related

Options

The commands in this section are used to run diagnostic tests.

5.19.1

Start Controller Diagnostics

Use the command in the following table to start the controller diagnostic for a set
amount of time.

Table 119: Flash Firmware in Mode 0 with ROM File

Convention

MegaCli –AdpM0Flash –f filename

Description

Flashes the firmware in Mode 0 with the ROM file listed on the command
line.
This option supports the Mode 0 flash functionality. For Mode 0 flash, the
controller number is not valid. The method to handle this function, is to flash
the firmware on all present controllers which are compatible with the image.

Table 120: Display PHY Connection Information

Convention

MegaCli –PHYInfo -phyM –aN|-a0,1,2|-aALL

Description

Displays PHY connection information for physical PHY M on the controllers.

Table 121: Start Diagnostics Setting

Convention

MegaCli –AdpDiag [val] –aN|-a0,1,2|-aALL

Description

Sets the amount of time for the controller diagnostic to run.

Val

: Indicates the time in seconds for the controller diagnostic to run.