2 flash the firmware in mode 0 with the rom file, 18 sas topology, 19 diagnostic-related options – Avago Technologies MegaRAID Fast Path Software User Manual
Page 264: 1 start controller diagnostics
Page 264
LSI Corporation Confidential
|
July 2011
MegaRAID SAS Software User Guide
Chapter 5: MegaRAID Command Tool
|
SAS Topology
5.17.2
Flash the Firmware in Mode 0
with the ROM File
Use the command in the following table to flash the firmware in Mode 0 with the ROM
file specified at the command line for the selected controllers. This command is only
supported for MS-DOS.
5.18
SAS Topology
The commands in this section are used to display SAS topology.
Use the command in the following table to display the PHY connection information for
physical PHY M on the selected controllers. Each PHY can form one side of the physical
link in a connection with a PHY on a different device. The physical link contains four
wires that form two differential signal pairs. One differential pair transmits signals, and
the other differential pair receives signals. Both differential pairs operate
simultaneously and allow concurrent data transmission in both the receive and the
transmit directions. PHYs are contained within ports.
A port can contain a single PHY or can contain multiple PHYs. A narrow port contains a
single PHY, and a wide port contains multiple PHYs.
5.19
Diagnostic-Related
Options
The commands in this section are used to run diagnostic tests.
5.19.1
Start Controller Diagnostics
Use the command in the following table to start the controller diagnostic for a set
amount of time.
Table 119: Flash Firmware in Mode 0 with ROM File
Convention
MegaCli –AdpM0Flash –f filename
Description
Flashes the firmware in Mode 0 with the ROM file listed on the command
line.
This option supports the Mode 0 flash functionality. For Mode 0 flash, the
controller number is not valid. The method to handle this function, is to flash
the firmware on all present controllers which are compatible with the image.
Table 120: Display PHY Connection Information
Convention
MegaCli –PHYInfo -phyM –aN|-a0,1,2|-aALL
Description
Displays PHY connection information for physical PHY M on the controllers.
Table 121: Start Diagnostics Setting
Convention
MegaCli –AdpDiag [val] –aN|-a0,1,2|-aALL
Description
Sets the amount of time for the controller diagnostic to run.
Val
: Indicates the time in seconds for the controller diagnostic to run.
- MegaRAID SAS 9240-4i MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SafeStore Software MegaRAID SAS 9361-4i MegaRAID SAS 9361-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID CacheCade Pro 2.0 Software MegaRAID SAS 9341-4i MegaRAID SAS 9341-8i MegaRAID SAS 9380-8e MegaRAID SAS 9380-4i4e