8 emergency hotspare support – Avago Technologies MegaRAID Fast Path Software User Manual
Page 320

Page 320
LSI Corporation Confidential
|
July 2011
MegaRAID SAS Software User Guide
Chapter 7: MegaRAID Storage Manager Window and Menus
|
MegaRAID Storage Manager Main Menu
NOTE: The size units displayed are as follows:
If the size is less than 1 MB (1024 KB), the size is displayed in KB. If the size is greater than
or equal to 1 MB but less than 1 GB (1024 MB), the size is displayed in MB. If the size is
greater than or equal to 1 GB, but less than 1 TB (1024 GB), the size is displayed in GB.
7.2.8
Emergency HotSpare Support
When a drive within a redundant virtual drive fails or is removed, the MegaRAID
firmware automatically rebuilds the redundancy of the virtual drive by providing an
Emergency Hotspare (EHSP) drive, even if no commissionable dedicated or global
hot spare drive is present.
7.2.8.1
Emergency Hotspare for
Physical Drives
The Emergency Hotspare property determines whether a particular drive is capable of
becoming an Emergency Hotspare. This property is displayed under the controller
properties only if the Global Hotspare for Emergency, and the Unconfigured Good for
Emergency controller properties are enabled.
Follow these steps to view the Emergency Hotspare property.
1. In the Logical view or the Physical view, click the drive that you want to view hot
spare properties.
2. The Emergency Hotspare is displayed under general properties. This property
denotes whether a particular drive is capable of becoming a Hotspare, as shown in
the following figure.
Figure 187: Emergency Hot Spare – Physical Drive Properties
7.2.8.2
Emergency Hotspare
Property for Controllers
The Emergency Hotspare properties under the controller properties are configured
based on enabling or disabling the following properties:
Global Hotspare for Emergency
Unconfigured Good for Emergency
Emergency for SMARTer
- MegaRAID SAS 9240-4i MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SafeStore Software MegaRAID SAS 9361-4i MegaRAID SAS 9361-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID CacheCade Pro 2.0 Software MegaRAID SAS 9341-4i MegaRAID SAS 9341-8i MegaRAID SAS 9380-8e MegaRAID SAS 9380-4i4e