Viewing and Changing Device Properties

Figure 106: Config Utility Battery Module Dialog for an iBBU Battery

Most of the battery module properties are view-only and are self-explanatory.

The following table gives a description of each of the BBU modes.

Table 22: BBU Modes

Mode of Operation

MR_MFC_DEFAULTS.bbu

Mode

Description

0

48 hours retention @ 60oC, 1 year Service Life

1

12 hours retention @ 45oC, 5 year Service Life,
transparent learn

2

12 hours retention @ 55oC, 3 year Service Life,
transparent learn

3

24 hours retention @ 45oC, 3 year Service Life,
transparent learn

4

48 hours retention @ 45oC, 3 year Service Life

5

48 hours retention @ 55oC, 1 year Service Life

6

Same as the description for BBU mode 5. The BBU
mode 6 enables you to get events when the battery
capacity reaches sub-optimal and critical thresholds.