0x0100
Warning
VD %s disabled because SAS drives are not supported by this
RAID key
0x0101
Warning
PD missing: %s
0x0102
Warning
Puncturing of LBAs enabled
0x0103
Warning
Puncturing of LBAs disabled
0x0104
Critical
Enclosure %s EMM %d not installed
0x0105
Information
Package version %s
0x0106
Warning
Global affinity Hot Spare %s commissioned in a different
enclosure
0x0107
Warning
Foreign configuration table overflow
0x0108
Warning
Partial foreign configuration imported, PDs not imported:%s
0x0109
Information
Connector %s is active
0x010a
Information
Board Revision %s
0x010b
Warning
Command timeout on PD %s, CDB:%s
0x010c
Warning
PD %s reset (Type %02x)
0x010d
Warning
VD bad block table on %s is 80% full
0x010e
Fatal
VD bad block table on %s is full; unable to log block %lx (on
%s at %lx)
0x010f
Fatal
Uncorrectable medium error logged for %s at %lx (on %s at
%lx)
0x0110
Information
VD medium error corrected on %s at %lx
0x0111
Warning
Bad block table on PD %s is 100% full
0x0112
Warning
VD bad block table on PD %s is 100% full
0x0113
Fatal
Controller needs replacement, IOP is faulty
0x0114
Information
CopyBack started on PD %s from PD %s
0x0115
Information
CopyBack aborted on PD %s and src is PD %s
0x0116
Information
CopyBack complete on PD %s from PD %s
0x0117
Progress
CopyBack progress on PD %s is %s
0x0118
Information
CopyBack resumed on PD %s from %s
0x0119
Information
CopyBack automatically started on PD %s from %s
0x011a
Critical
CopyBack failed on PD %s due to source %s error
0x011b
Warning
Early Power off warning was unsuccessful
0x011c
Information
BBU FRU is %s
0x011d
Information
%s FRU is %s
0x011e
Information
Controller hardware revision ID %s
0x011f
Warning
Foreign import shall result in a backward incompatible
upgrade of configuration metadata
0x0120
Information
Redundant path restored for PD %s
0x0121
Warning
Redundant path broken for PD %s
0x0122
Information
Redundant enclosure EMM %s inserted for EMM %s
Table 150: Event Messages (Continued)
Number
Severity Level
Event Text
- MegaRAID SAS 9240-4i MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SafeStore Software MegaRAID SAS 9361-4i MegaRAID SAS 9361-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID CacheCade Pro 2.0 Software MegaRAID SAS 9341-4i MegaRAID SAS 9341-8i MegaRAID SAS 9380-8e MegaRAID SAS 9380-4i4e