beautypg.com

Avago Technologies MegaRAID Fast Path Software User Manual

Page 87

background image

LSI Corporation Confidential

|

July 2011

Page 87

MegaRAID SAS Software User Guide

Chapter 4: WebBIOS Configuration Utility

|

Creating a Storage Configuration

4.5.2.5

Using Manual

Configuration: RAID 00

A RAID 00 drive group is a spanned drive group that creates a striped set from a series
of RAID 0 drive groups. It breaks up data into smaller blocks and then stripes the blocks
of data to RAID 00 drive groups. The size of each block is determined by the stripe size
parameter, which is 64 KB.

RAID 00 does not provide any data redundancy but does offer excellent performance.
RAID 00 is ideal for applications that require high bandwidth but do not require fault
tolerance.

When you select Manual Configuration and click Next, the WebBIOS Drive Group
Definition dialog appears.

You use the Drive Group Definition dialog to select drives to create drive groups.

1. Hold Ctrl key while you select ready drives in the Drives panel on the left.

2. Click Add To Array to move the drives to a proposed drive group configuration in

the Drive Groups panel on the right.

3. If you need to undo the changes, click Reclaim.

4. Click Accept DG to create a RAID 0 drive group.

An icon for the next drive group appears in the right panel.

5. Hold the Ctrl key while you select more ready drives in the Drives panel to create a

second RAID 0 drive group.

6. Click Add To Array to move the drives to a second drive group configuration in the

Drive Groups panel, as shown in

Figure 44

.

If you need to undo the changes, click Reclaim.

NOTE: RAID 00 supports a maximum of eight spans, with a maximum of 32 drives per
span. (Other factors, such as the type of controller, can limit the number of drives.)

7. Choose whether to use drive encryption.

8. Click Accept DG to create a RAID 0 drive group.