Chapter 5: MegaRAID Command Tool

|

Controller Property-Related Options

5.8.6

Display Specified Controller

Properties

Use the command in the following table to display specified properties on the selected
controllers.

NOTE: The tty log can be saved at the controller level.

5.8.7

Set Factory Defaults

Use the command in the following table to set the factory defaults on the selected
controllers.

5.8.8

Set SAS Address

Use the command in the following table to set the SAS address on the selected
controllers.

Table 52: Display Specified Controller Properties

Convention

MegaCli –AdpGetProp CacheFlushInterval | RebuildRate | PatrolReadRate| BgiRate |
CCRate | ReconRate | SpinupDriveCount | SpinupDelay | CoercionMode |
PredFailPollInterval | ClusterEnable | BatWarnDsbl | EccBucketSize | EccBucketLeakRate
| EccBucketCount | AlarmDsply | AbortCCOnError | AutoDetectBackPlaneDsbl |
CopyBackDsbl | LoadBalanceMode | SMARTCpyBkEnbl | SSDSMARTCpyBkEnbl |
MaintainPdFailHistoryEnbl | EnblSpinDownUnConfigDrvs | EnblSSDPatrolRead | NCQDsply |
UseFDEOnlyEncrypt | WBSupport | AutoEnhancedImportDsbl | PrCorrectUncfgdAreas |
DsblSpinDownUnConfigDrvs | ENABLEEGHSP | ENABLEEUG | ENABLEESMARTER -aN|-a0,1,2|-aALL

Description

Displays the properties on the selected controllers.

EccBucketCount

: Count of single-bit ECC errors currently in the bucket.

WBSupport

: Enables support for the Write Back option as the Write Policy.

DsblSpinDownUnConfigDrvs

: Disable spindown of unconfigured drives.

ENABLEEGHSP

: Enable global hot spare is three bits or adapter level for setting hot spare properties.

Values: 0= Disable and 1: Enable.

ENABLEEUG

: Enable unconfigured good for emergency is three bits or adapter level for setting hot spare properties.

Values: 0= Disable and 1: Enable

ENABLEESMARTER

: Emergency for SMARTer is three bits or adapter level for setting hot spare properties.

Values: 0= Disable and 1: Enable

See

Table 51

for explanations of the other options.

Table 53: Set Factory Defaults

Convention

MegaCli -AdpFacDefSet -aN|-a0,1,2|-aALL

Description

Sets the factory defaults on the selected controllers.

Table 54: Set SAS Address on Controller

Convention

MegaCli –AdpSetSASA str[0-64] -aN

Description

Sets the controller’s SAS address. This string must be a 64-digit hexadecimal