beautypg.com

Avago Technologies MegaRAID Fast Path Software User Manual

Page 477

background image

LSI Corporation Confidential

|

July 2011

Page 477

MegaRAID SAS Software User Guide

Appendix A: Events and Messages

|

Event Messages

0x0074

Warning

Redundant path to %s broken

0x0075

Information

Redundant path to %s restored

0x0076

Information

Dedicated Hot Spare Drive %s no longer useful due to deleted
drive group

0x0077

Critical

SAS topology error: Loop detected

0x0078

Critical

SAS topology error: Unaddressable device

0x0079

Critical

SAS topology error: Multiple ports to the same SAS address

0x007a

Critical

SAS topology error: Expander error

0x007b

Critical

SAS topology error: SMP timeout

0x007c

Critical

SAS topology error: Out of route entries

0x007d

Critical

SAS topology error: Index not found

0x007e

Critical

SAS topology error: SMP function failed

0x007f

Critical

SAS topology error: SMP CRC error

0x0080

Critical

SAS topology error: Multiple subtractive

0x0081

Critical

SAS topology error: Table to table

0x0082

Critical

SAS topology error: Multiple paths

0x0083

Fatal

Unable to access device %s

0x0084

Information

Dedicated Hot Spare created on %s (%s)

0x0085

Information

Dedicated Hot Spare %s disabled

0x0086

Critical

Dedicated Hot Spare %s no longer useful for all drive groups

0x0087

Information

Global Hot Spare created on %s (%s)

0x0088

Information

Global Hot Spare %s disabled

0x0089

Critical

Global Hot Spare does not cover all drive groups

0x008a

Information

Created %s}

0x008b

Information

Deleted %s}

0x008c

Information

Marking LD %s inconsistent due to active writes at shutdown

0x008d

Information

Battery Present

0x008e

Warning

Battery Not Present

0x008f

Information

New Battery Detected

0x0090

Information

Battery has been replaced

0x0091

Critical

Battery temperature is high

0x0092

Warning

Battery voltage low

0x0093

Information

Battery started charging

0x0094

Information

Battery is discharging

0x0095

Information

Battery temperature is normal

0x0096

Fatal

Battery has failed and cannot support data retention. Please
replace the battery.

0x0097

Information

Battery relearn started

0x0098

Information

Battery relearn in progress

Table 150: Event Messages (Continued)

Number

Severity Level

Event Text