Avago Technologies MegaRAID Fast Path Software User Manual
Page 477

LSI Corporation Confidential
|
July 2011
Page 477
MegaRAID SAS Software User Guide
Appendix A: Events and Messages
|
Event Messages
0x0074
Warning
Redundant path to %s broken
0x0075
Information
Redundant path to %s restored
0x0076
Information
Dedicated Hot Spare Drive %s no longer useful due to deleted
drive group
0x0077
Critical
SAS topology error: Loop detected
0x0078
Critical
SAS topology error: Unaddressable device
0x0079
Critical
SAS topology error: Multiple ports to the same SAS address
0x007a
Critical
SAS topology error: Expander error
0x007b
Critical
SAS topology error: SMP timeout
0x007c
Critical
SAS topology error: Out of route entries
0x007d
Critical
SAS topology error: Index not found
0x007e
Critical
SAS topology error: SMP function failed
0x007f
Critical
SAS topology error: SMP CRC error
0x0080
Critical
SAS topology error: Multiple subtractive
0x0081
Critical
SAS topology error: Table to table
0x0082
Critical
SAS topology error: Multiple paths
0x0083
Fatal
Unable to access device %s
0x0084
Information
Dedicated Hot Spare created on %s (%s)
0x0085
Information
Dedicated Hot Spare %s disabled
0x0086
Critical
Dedicated Hot Spare %s no longer useful for all drive groups
0x0087
Information
Global Hot Spare created on %s (%s)
0x0088
Information
Global Hot Spare %s disabled
0x0089
Critical
Global Hot Spare does not cover all drive groups
0x008a
Information
Created %s}
0x008b
Information
Deleted %s}
0x008c
Information
Marking LD %s inconsistent due to active writes at shutdown
0x008d
Information
Battery Present
0x008e
Warning
Battery Not Present
0x008f
Information
New Battery Detected
0x0090
Information
Battery has been replaced
0x0091
Critical
Battery temperature is high
0x0092
Warning
Battery voltage low
0x0093
Information
Battery started charging
0x0094
Information
Battery is discharging
0x0095
Information
Battery temperature is normal
0x0096
Fatal
Battery has failed and cannot support data retention. Please
replace the battery.
0x0097
Information
Battery relearn started
0x0098
Information
Battery relearn in progress
Table 150: Event Messages (Continued)
Number
Severity Level
Event Text
- MegaRAID SAS 9240-4i MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SafeStore Software MegaRAID SAS 9361-4i MegaRAID SAS 9361-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID CacheCade Pro 2.0 Software MegaRAID SAS 9341-4i MegaRAID SAS 9341-8i MegaRAID SAS 9380-8e MegaRAID SAS 9380-4i4e