Viewing and Changing Device Properties
Select Enclosure Affinity so drive failures are present on a split backplane
configuration, then the hot spare will be used first on the backplane side in which it
resides.
Select Prepare for Removal to prepare the drive for removal from the enclosure.
The Prepare for Removal feature is different from spinning a drive down into
power save mode because it also involves flagging the drive as ready to remove.
Therefore, if you choose to prepare a drive for removal, selecting Ready to Remove
displays in the device tree for that drive, instead of Powersave.
Select Stop Locate to stop the LED flash on the drive. This works only if the drive is
installed in a drive enclosure.
Select Drive Erase to securely erase data on non self-encrypting drives (Non-SED),
which are normal HDDs.
4.8.4
Shield State
Physical devices in MegaRAID firmware transit between different states. If the firmware
detects a problem or a communication loss for a physical drive, the firmware transitions
the drive to a bad (FAILED or UNCONF BAD) state. To avoid transient failures, an interim
state called the shield state is introduced before marking the drive as being in a bad
state.
The shield state is an interim state of a physical drive for diagnostic operations. The
results of the diagnostic tests determine if the physical drive is good or bad. If any of
the diagnostic tests fail, the physical drive transitions to a bad state (FAILED or UNCONF
BAD).
4.8.4.1
Shield State Physical
View
Follow these steps to check if a physical drive is in a Shield state in the Physical view.
1. Click Physical View in the main dialog.
The physical drive that is in a shield state is marked as Shielded.
- MegaRAID SAS 9240-4i MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SafeStore Software MegaRAID SAS 9361-4i MegaRAID SAS 9361-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID CacheCade Pro 2.0 Software MegaRAID SAS 9341-4i MegaRAID SAS 9341-8i MegaRAID SAS 9380-8e MegaRAID SAS 9380-4i4e