Chapter 5: MegaRAID Command Tool
|
Drive-Related Options
5.15.11 Replace the Configured Drives
and Start an Automatic Rebuild
Use the command in the following table to replace configured drives and start an
automatic rebuild of the drive for the selected controllers.
5.15.12 Prepare the Unconfigured
Drive for Removal
Use the command in the following table to prepare the unconfigured drives for
removal from the selected controllers.
5.15.13 Display Total Number of Drives
Use the command in the following table to display the total number of drives attached
to an controller. Drives can be attached directly or through enclosures.
Table 107: Replace Configured Drives and Start Automatic Rebuild
Convention
MegaCli –PDReplaceMissing –PhysDrv[E0:S0,E1:S1....]
-ArrayX -RowY -aN
Description
Replaces the configured drives that are identified as missing and then starts
an automatic rebuild.
-Physdrv[E0:S0,...]
: Specifies the physical drive enclosure and the
slots for the drives.
Table 108: Prepare Unconfigured Drives for Removal
Convention
MegaCli –PDPrpRmv [-Undo] – PhysDrv[E0:S0,E1:S1....]
-aN|-a0,1,2|-aALL
Description
Prepares unconfigured drives for removal. The firmware spins down this
drive. The drive state is set to Unaffiliated, which marks it as offline even
though it is not a part of a configuration.
-Undo
: This option undoes this operation. If you select undo, the firmware
marks this drive as Unconfigured Good.
-Physdrv[E0:S0,...]
: Specifies the physical drive enclosure and the
slots for the drives.
Table 109: Display Number of Drives Attached to an Controller
Convention
MegaCli –PDGetNum –aN|-a0,1,2|-aALL
Description
Displays the total number of drives attached to an controller. Drives can be
attached directly or through enclosures. The return value is the number of
drives.
- MegaRAID SAS 9240-4i MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SafeStore Software MegaRAID SAS 9361-4i MegaRAID SAS 9361-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID CacheCade Pro 2.0 Software MegaRAID SAS 9341-4i MegaRAID SAS 9341-8i MegaRAID SAS 9380-8e MegaRAID SAS 9380-4i4e