Avago Technologies MegaRAID Fast Path Software User Manual
Page 78
Page 78
LSI Corporation Confidential
|
July 2011
MegaRAID SAS Software User Guide
Chapter 4: WebBIOS Configuration Utility
|
Creating a Storage Configuration
In addition, RAID 5 is good for any application that has high read request rates but low
write request rates.
When you select Manual Configuration and click Next, the Drive Group Definition
dialog appears. You use this dialog to select drives to create drive groups.
1. Hold Ctrl while you select at least three ready drives in the Physical Drives panel
on the left.
2. Click Add To Array to move the drives to a proposed drive group configuration in
the Drive Groups panel on the right, as shown in
3. If you need to undo the changes, click Reclaim.
4. Choose whether to use power save mode.
5. Choose whether to use drive encryption.
Figure 38:
Drive Group Definition Dialog
6. After you finish selecting drives for the drive group, click Accept DG.
7. Click Next.
The Virtual Drive Definition dialog appears, as shown in
. You use this
dialog to select the RAID level, strip size, read policy, and other attributes for the
new virtual drives.
- MegaRAID SAS 9240-4i MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SafeStore Software MegaRAID SAS 9361-4i MegaRAID SAS 9361-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID CacheCade Pro 2.0 Software MegaRAID SAS 9341-4i MegaRAID SAS 9341-8i MegaRAID SAS 9380-8e MegaRAID SAS 9380-4i4e