beautypg.com

2 delete a solid state drive cache drive, 3 associate/disassociate virtual drives – Avago Technologies MegaRAID Fast Path Software User Manual

Page 222

background image

Page 222

LSI Corporation Confidential

|

July 2011

MegaRAID SAS Software User Guide

Chapter 5: MegaRAID Command Tool

|

CacheCade Related Options

5.5.1

Create a Solid State Drive

Cache Drive to Use as Secondary Cache

Use the command in the following table to create a cache drive using CacheCade 2.0
SSD Read Caching software. You can use that cache as secondary cache. CacheCade 2.0
SSD Read Caching software has much greater capacity than HDDs.

5.5.2

Delete a Solid State Drive

Cache Drive

Use the command in the following table to delete a CacheCade 2.0 SSD Read Caching
software cache drive or multiple cache drives on the selected controllers.

5.5.3

Associate/Disassociate Virtual

Drives

Use this command in the following table to associate or disassociate virtual drives with
a CacheCade Pro 2.0 virtual drive.

5.5.4

Display CacheCade Pro 2.0

Configurations on a Controller

Use this command in the following table to display all the existing CacheCade Pro 2.0
configurations on a selected controller.

Table 26: Create a Solid State Cache Drive to Use as Secondary Cache

Convention

MegaCli -CfgCachecadeAdd -Physdrv[E0:S0,...] {-Name
LdNamestring} -aN|-a0,1,2|-aALL

Description

This command is used to create CacheCade software that you can use as
secondary cache.

-Physdrv[E0:S0,...]

: Specifies the physical drive enclosure and the

slots to use to construct a drive group.

-Name LdNamestring

: This is the name given to the CacheCade

software cache drive.

Table 27: Delete Solid State Cache Drives

Convention

MegaCli -CfgCachecadeDel -LX|-L0,2,5...|-LALL
-aN|-a0,1,2|-aALL

Description

Deletes the specified CacheCade software cache drive or drives on the
selected controllers. You can delete multiple CacheCade software cache
drives or all of the CacheCade software caches.

Table 28: Associate/Disassociate Virtual Drives

Convention

MegaCLI -Cachecade -assign|-remove
-Lx|-L0,1,2|-LALL -aN|-a0,1,2|-aALL

Description

Assigns or removes association of virtual drives with the CacheCade pool.

-assign: associates virtual drives with a CacheCade Pro 2.0 virtual drive.

-remove: disassociates virtual drives with a CacheCade Pro 2.0 virtual drive.

Table 29: Display CacheCade Pro 2.0 Configurations on a Controller

Convention

MegaCLI -CfgCacheCadeDsply -aN|-a0,1,2|-aALL

Description

Displays all the existing CacheCade Pro 2.0 configurations on a selected
controller.