beautypg.com

Avago Technologies MegaRAID Fast Path Software User Manual

Page 479

background image

LSI Corporation Confidential

|

July 2011

Page 479

MegaRAID SAS Software User Guide

Appendix A: Events and Messages

|

Event Messages

0x00bd

Information

SAS/SATA mixing not supported in enclosure; Drive %s
disabled

0x00be

Information

Enclosure (SES) hotplug on %s was detected, but is not
supported

0x00bf

Information

Clustering enabled

0x00c0

Information

Clustering disabled

0x00c1

Information

Drive too small to be used for auto-rebuild on %s

0x00c2

Information

BBU enabled; changing WT virtual drives to WB

0x00c3

Warning

BBU disabled; changing WB virtual drives to WT

0x00c4

Warning

Bad block table on drive %s is 80% full

0x00c5

Fatal

Bad block table on drive %s is full; unable to log block %lx

0x00c6

Information

Consistency Check Aborted due to ownership loss on %s

0x00c7

Information

Background Initialization (BGI) Aborted Due to Ownership
Loss on %s

0x00c8

Critical

Battery/charger problems detected; SOH Bad

0x00c9

Warning

Single-bit ECC error: ECAR=%x, ELOG=%x, (%s); warning
threshold exceeded

0x00ca

Critical

Single-bit ECC error: ECAR=%x, ELOG=%x, (%s); critical
threshold exceeded

0x00cb

Critical

Single-bit ECC error: ECAR=%x, ELOG=%x, (%s); further
reporting disabled

0x00cc

Critical

Enclosure %s Power supply %d switched off

0x00cd

Information

Enclosure %s Power supply %d switched on

0x00ce

Critical

Enclosure %s Power supply %d cable removed

0x00cf

Information

Enclosure %s Power supply %d cable inserted

0x00d0

Information

Enclosure %s Fan %d returned to normal

0x00d1

Information

BBU Retention test was initiated on previous boot

0x00d2

Information

BBU Retention test passed

0x00d3

Critical

BBU Retention test failed!

0x00d4

Information

NVRAM Retention test was initiated on previous boot

0x00d5

Information

NVRAM Retention test passed

0x00d6

Critical

NVRAM Retention test failed!

0x00d7

Information

%s test completed %d passes successfully

0x00d8

Critical

%s test FAILED on %d pass. Fail data: errorOffset=%x
goodData=%x badData=%x

0x00d9

Information

Self check diagnostics completed

0x00da

Information

Foreign Configuration detected

0x00db

Information

Foreign Configuration imported

0x00dc

Information

Foreign Configuration cleared

0x00dd

Warning

NVRAM is corrupt; reinitializing

Table 150: Event Messages (Continued)

Number

Severity Level

Event Text