Avago Technologies MegaRAID Fast Path Software User Manual
Page 479

LSI Corporation Confidential
|
July 2011
Page 479
MegaRAID SAS Software User Guide
Appendix A: Events and Messages
|
Event Messages
0x00bd
Information
SAS/SATA mixing not supported in enclosure; Drive %s
disabled
0x00be
Information
Enclosure (SES) hotplug on %s was detected, but is not
supported
0x00bf
Information
Clustering enabled
0x00c0
Information
Clustering disabled
0x00c1
Information
Drive too small to be used for auto-rebuild on %s
0x00c2
Information
BBU enabled; changing WT virtual drives to WB
0x00c3
Warning
BBU disabled; changing WB virtual drives to WT
0x00c4
Warning
Bad block table on drive %s is 80% full
0x00c5
Fatal
Bad block table on drive %s is full; unable to log block %lx
0x00c6
Information
Consistency Check Aborted due to ownership loss on %s
0x00c7
Information
Background Initialization (BGI) Aborted Due to Ownership
Loss on %s
0x00c8
Critical
Battery/charger problems detected; SOH Bad
0x00c9
Warning
Single-bit ECC error: ECAR=%x, ELOG=%x, (%s); warning
threshold exceeded
0x00ca
Critical
Single-bit ECC error: ECAR=%x, ELOG=%x, (%s); critical
threshold exceeded
0x00cb
Critical
Single-bit ECC error: ECAR=%x, ELOG=%x, (%s); further
reporting disabled
0x00cc
Critical
Enclosure %s Power supply %d switched off
0x00cd
Information
Enclosure %s Power supply %d switched on
0x00ce
Critical
Enclosure %s Power supply %d cable removed
0x00cf
Information
Enclosure %s Power supply %d cable inserted
0x00d0
Information
Enclosure %s Fan %d returned to normal
0x00d1
Information
BBU Retention test was initiated on previous boot
0x00d2
Information
BBU Retention test passed
0x00d3
Critical
BBU Retention test failed!
0x00d4
Information
NVRAM Retention test was initiated on previous boot
0x00d5
Information
NVRAM Retention test passed
0x00d6
Critical
NVRAM Retention test failed!
0x00d7
Information
%s test completed %d passes successfully
0x00d8
Critical
%s test FAILED on %d pass. Fail data: errorOffset=%x
goodData=%x badData=%x
0x00d9
Information
Self check diagnostics completed
0x00da
Information
Foreign Configuration detected
0x00db
Information
Foreign Configuration imported
0x00dc
Information
Foreign Configuration cleared
0x00dd
Warning
NVRAM is corrupt; reinitializing
Table 150: Event Messages (Continued)
Number
Severity Level
Event Text
- MegaRAID SAS 9240-4i MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SafeStore Software MegaRAID SAS 9361-4i MegaRAID SAS 9361-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID CacheCade Pro 2.0 Software MegaRAID SAS 9341-4i MegaRAID SAS 9341-8i MegaRAID SAS 9380-8e MegaRAID SAS 9380-4i4e