5 limitations – Avago Technologies MegaRAID Fast Path Software User Manual
Page 292

Page 292
LSI Corporation Confidential
|
July 2011
MegaRAID SAS Software User Guide
Chapter 6: MegaRAID Storage Manager Overview and Installation
|
MegaRAID Storage Manager Support and Instal-
lation on VMware
NOTE: There is a known limitation that virtual drives that are created or deleted will not
be reflected to the kernel. The workaround is to reboot the server or to run
esxcfg-rescan
from COS shell.
6.5.4
MegaRAID Storage Manager
Support on the VMware ESXi Operating
System
This section outlines the product requirements needed to support the VMware ESXi
operating system. Classic VMware includes a service console that is derived from the
Linux 2.4 kernel, but with reduced functionality.
The MegaRAID Storage Manager server part cannot be installed directly in the VMware
ESXi operating system. Management is possible only through Common Information
Model (CIM) providers. These CIM providers integrated into the VMware ESXi system
build an interface between the hardware driver of the LSI MegaRAID controller and
remote applications, such as the MegaRAID Storage Manager software. Management is
performed through the MegaRAID Storage Manager software installed on a remote
machine (Linux/Windows).
VMware ESXi comes with the Small Footprint CIM Broker (CFCB) CIM Object Manager
(or CIMOM). A CIMOM manages the communication between providers, which
interacts with the hardware, and a CIM client, where the administrator manages the
system.
SFCB supports Common Manageability Programming Interface (CMPI)-style providers.
CMPI defines a common standard used to interface Manageability Instrumentation
(providers, instrumentation) to Management Brokers (CIM Object Manager). CMPI
standardizes Manageability Instrumentation, which lets you write and build
instrumentation once and run it in different CIM environments (on one platform).
Network communication is a key element for a proper communication between the
ESXi CIM provider and the LSI management software. Please make sure that the
network settings are correct by making the following changes:
For networks that do not have DNS configured, the “hosts” file in the machine on
which the MegaRAID Storage Manager software is installed must be edited as
follows:
a. Add an entry to map the VMware host’s IP address with the host name. This is for
the discovery process to happen correctly. In the absence of this entry, the
VMware host would be discovered as 0.0.0.0.
b. Add an entry to map its own IP address (not the loop back address) with the
Hostname. This is to ensure that the Asynchronous Event Notifications (AENs)
are delivered correctly.
For networks that have DNS configured, perform the following:
a. Provide the correct DNS server IP address when you do the initial configurations
for the VMware host.
b. In the hosts file of the machine on which the MegaRAID Storage Manager
software is installed, add an entry to map its own IP address (not the loop back
address) with the host name, to ensure that the Asynchronous Event
Notifications are delivered correctly.
6.5.5
Limitations
The following are the limitations of this installation and configuration.
No status information exists for the controller
- MegaRAID SAS 9240-4i MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SafeStore Software MegaRAID SAS 9361-4i MegaRAID SAS 9361-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID CacheCade Pro 2.0 Software MegaRAID SAS 9341-4i MegaRAID SAS 9341-8i MegaRAID SAS 9380-8e MegaRAID SAS 9380-4i4e