IC6 Operating Manual

Operate Display Description

1 Aggregate Rate

2 Layer Thickness

3 Power Level

4 State of Layer

5 State Timer

6 Layer Currently In Process

7 Layer Timer

8 Material Being Deposited

9 Source Number In Use

10 Sensor Number(s) In Use

11 Crystal Position In Use

12 Graphical Display of Rate Deviation or Power

13 Process Being Executed & Process Time

14 Run Number

15 Date and Time

16 Message Area

17 Function Key Definitions

18 Crucible Position

During the OPERATE display, the function keys below the screen function as
explained in

Table 3-1

.

In addition to the standard operational screen, if the system is configured for
co-deposition, or multi-layer deposition, the operational screen will be divided to
show information for all layers as shown in

Figure 3-5

,

Figure 3-6

or

Figure 3-7

.

Table 3-1 Operate display function keys

Key Function

Description

F1

ZERO
THICKNESS

Pressing F1 resets the displayed thickness of the current layer and
the sensor thickness values to zero.

F2

TOGGLE
MANUAL

Press F2 to put the layer in manual control so that the power level
is controlled by the Handheld Controller (

section 3.6.6

). When in

Manual, press F2 again to remove the layer from the Manual state
and place it into the DEPOSIT state.

F3

SHOW ALL
LAYERS/
SHOW GRAPH

Press F3 to toggle between showing all layers (if more are
running) or showing only one layer