746

Multi-Service IronWare Routing Configuration Guide

53-1003033-02

IPv6 IS-IS Multi-Topology

The initial-hold-time variable specifies the initial time gap between an SPF event and the first
running of SPF. The range is from 0 through 120000 milliseconds. The default value is 5000
milliseconds.

The exponential-hold-time variable specifies the interval between two SPF calculations. The range
is from 0 through 120000 milliseconds. The default value is 5000 milliseconds.

The [no] form of the command resets all parameters to their default values.

Changing the metric added value

When the device calculates a route, the device adds a metric (cost) to the route. Each IS-IS
interface has a separate metric value. In IPv6 IS-IS MT, different metrics are configured on an
interface for IPv4 and IPv6. When the metric value is configured for an interface, it rebuilds the
route LSP and triggers IPv6 IS-IS MT SPF calculation.

To configure the metric value for an interface under IPv6 IS-IS MT, enter the following command.

Brocade(config-if-e10000-1/4)# isis ipv6 metric 15

Syntax: [no] isis ipv6 metric value [level-1 | level-2]

The value variable specifies the metric. The metric range depends on the metric style. You can
specify the range from 1 through 63 for the narrow metric style and from 1 through 16777215 for
the wide metric style. The default value for both styles is 10.

The level-1 option specifies that the level 1 router routes traffic only within an area. To forward
traffic to another area, the level 1 router sends the traffic to its nearest level-2 router.

The level-2 option specifies that the level 2 router routes traffic between the areas within a domain.
The level-1 | level-2 options apply the change to only the level you specify. If you do not use one of
the options, the change applies to both the levels.