Refreshing end-to-end monitor pairs
Procedures in this section pertain to refreshing monitors on systems using the legacy End-to-End
Monitor feature instead of using Flow Vision.
For systems using Fabric OS version 7.2 or later, when you select a device or device port, and then
select Monitor > Performance > End-to-End Monitors, a message displays that you can use Flow
Vision to provide End-to-End monitoring. You have these options:
•
To use Flow Vision, delete existing monitors, then use the Add Flow Definition dialog box to
define an initiator and target port pair for monitoring. Refer to
for
more information.
•
Clicking OK, opens the legacy Set End-To-End Monitors dialog box.To use the legacy End-to-End
Monitor feature, you must deactivate existing flows defined for the switch for Flow Vision.
The Management application enables you to rewrite the end-to-end monitors (deleted through the
CLI or an Element Manager) back to a device.
To refresh all end-to-end monitor pairs, complete the following steps.
1. Select Monitor > Performance > End-to-End Monitors.
The Set End-to-End Monitor dialog box displays.
2. Click Refresh.
All end-to-end monitor pairs are rewritten back to any devices where the end-to-end monitor
pairs were deleted through the CLI or an Element Manager.
3. Click OK.
Deleting an end-to-end monitor pair
Procedures in this section pertain to deleting monitors on systems using the legacy End-to-End
Monitor feature instead of using Flow Vision.
For systems using Fabric OS version 7.2 or later, when you select a device or device port, and then
select Monitor > Performance > End-to-End Monitors, a message displays that you can use Flow
Vision to provide End-to-End monitoring. You have these options:
•
To use Flow Vision, delete existing monitors, then use the Add Flow Definition dialog box to
define an initiator and target port pair for monitoring. Refer to
for
more information.
•
Clicking OK, opens the legacy Set End-To-End Monitors dialog box.To use the legacy End-to-End
Monitor feature, you must deactivate existing flows defined for the switch for Flow Vision.
To delete an end-to-end monitor pair, complete the following steps.
1. Select Monitor > Performance > End-to-End Monitors.
The Set End-to-End Monitor dialog box displays.
2. Select the end-to-end monitor pair you want to delete from the Monitored Pairs list.
3. Click Delete Monitor.
4. Click OK.