beautypg.com

Displaying end-to-end, Monitor pairs in a real-time graph, Displaying end-to-end monitor pairs in a – Brocade Network Advisor SAN User Manual v12.1.0 User Manual

Page 1032: Historical graph

background image

984

Brocade Network Advisor SAN User Manual

53-1002948-01

SAN end-to-end monitoring

29

Displaying end-to-end monitor pairs in a real-time graph

Procedures in this section pertain to displaying monitors on systems using the legacy End-to-End
Monitor feature instead of using Flow Vision.

For systems using Fabric OS version 7.2 or later, when you select a device or device port, and then
select Monitor > Performance > End-to-End Monitors, a message displays that you can use Flow
Vision to provide End-to-End monitoring. You have these options:

To use Flow Vision, delete existing monitors, then use the Add Flow Definition dialog box to
define an initiator and target port pair for monitoring. Refer to

Chapter 30, “Flow Vision”

for

more information.

Clicking OK, opens the legacy Set End-To-End Monitors dialog box.To use the legacy End-to-End
Monitor feature, you must deactivate existing flows defined for the switch for Flow Vision.

To display an end-to-end monitor pair in a real-time graph, complete the following steps.

1. Select Monitor > Performance > End-to-End Monitors.

The Set End-to-End Monitor dialog box displays.

2. Select one or more end-to-end monitor pairs you want to view from the Monitored Pairs list.

You can select up to 100 monitored pairs.

3. Click Real-Time Graph.

The Real Time Performance Graphs dialog box displays.

Displaying end-to-end monitor pairs in a historical graph

Procedures in this section pertain to configuring monitors on systems using the legacy End-to-End
Monitor feature instead of using Flow Vision.

For systems using Fabric OS version 7.2 or later, when you select a device or device port, and then
select Monitor > Performance > End-to-End Monitors, a message displays that you can use Flow
Vision to provide End-to-End monitoring. You have these options:

To use Flow Vision, delete existing monitors, then use the Add Flow Definition dialog box to
define an initiator and target port pair for monitoring. Refer to

Chapter 30, “Flow Vision”

for

more information.

Clicking OK, opens the legacy Set End-To-End Monitors dialog box.To use the legacy End-to-End
Monitor feature, you must deactivate existing flows defined for the switch for Flow Vision.

To display monitored pairs in a historical graph, data collection must be enabled for the selected
fabric or enabled SAN-wide.

To display an end-to-end monitor pair in a historical graph, complete the following steps.

1. Select Monitor > Performance > End-to-End Monitors.

The Set End-to-End Monitor dialog box displays.

2. Select one or more end-to-end monitor pairs you want to view from the Monitored Pairs list.

You can select up to 100 monitored pairs.

3. Click Historical Graph.

The Historical Performance Graph dialog box displays.