Modify ping parameters, Modify web manager parameters, Configure – for specific device types – H3C Technologies H3C Intelligent Management Center User Manual
Page 339
325
The modify Poll Interval dialog box appears. The Configuration Poll Interval is the parameter that
determines how long IMC waits before polling managed devices for any configuration changes.
2.
Enter the configuration polling interval in minutes in the Configuration Poll Interval field.
The range is 5–1500 minutes and the default is 120 minutes. Like most management systems, IMC
uses ping to query devices for their status or reachability. The Status Poll Interval is the parameter
that determines how long IMC waits before sending ping requests to the managed device to
determine its reachability status.
3.
Enter the status-polling interval in minutes in the Status Poll Interval field.
The range is 30–600 seconds and the default is 60 seconds.
4.
Click OK to accept the polling interval configuration.
Modify ping parameters
To modify ping parameters for the selected device from the Device Details page:
1.
Click the Modify Ping Parameters link located under the Configure section of the right navigation
tree on the selected device's Device Details page.
For information on navigating to a device's Device Details page, see "
The modify Ping Parameters dialog box appears.
2.
Click the Support Ping Operation checkbox.
{
If you select the checkbox next to Support Ping Operation, IMC will use ping packets to
detect the reachability of devices.
{
If you clear the checkbox next to Support Ping Operation, IMC will use SNMP packets to
detect the reachability of devices.
3.
Click OK.
Modify Web manager parameters
To modify the communication parameters for Web Manager
1.
Click the Modify Web Manager Parameters link located under the Configure section of the right
navigation tree on the selected device's Device Details page.
For information on navigating to a device's Device Details page, see "
The modify Web Manager Parameters dialog box appears.
2.
Select the protocol that is used by Web Manager from the Protocol list.
3.
Enter the port number for Web Manager in the Port field.
4.
Click OK.
If you do not make a selection from the Protocol list and the selection for Protocol is blank, IMC uses
the global setting found under the System tab and the port value assigned is ignored.
Configure – For specific device types
IMC offers quick access to the ACL Management service module from the Device Details page. The ACL
Configuration link, which can be found under Configure on the right navigation tree for routers, redirects
you to the ACL Management service module found under the Service tab. For more information about the
ACL management features of IMC, see "