beautypg.com

Basler Electric DECS-250N User Manual

Page 289

background image

9440500990 Rev D

273

DECS-250N

PROFIBUS Communication

Instance Name

Inst. #

Type

RW

Key Name

Unit

Range

Synchronizer

152

Float

R/W

Sync Fail Activation

Delay GG

Sec

0.1 - 600

Synchronizer

152

Float

R/W

Sync Speed Gain GG

No

Unit

0.001 - 1000

Synchronizer

152

Float

R/W

Sync Voltage Gain GG

No

Unit

0.001 - 1000

Voltage Matching

153

UINT32 R/W

Sys Option Input Volt

Match Enabled GG

No

Unit

DISABLED=0 ENABLED=1

Voltage Matching

154

Float

R/W

Sys Option Vol Match

Band GG

%

0 - 20

Voltage Matching

154

Float

R/W

Sys Option Vol Match

Ref GG

%

0 - 700

Breaker Hardware

155

UINT32 R/W

Gen Breaker GG

No

Unit

Not Configured=0 Configured=1

Breaker Hardware

155

UINT32 R/W

Gen Contact Type GG

No

Unit

Pulse=0 Continuous=1

Breaker Hardware

155

UINT32 R/W

Dead Bus Close

Enable GG

No

Unit

DISABLED=0 ENABLED=1

Breaker Hardware

155

UINT32 R/W

Dead Gen Close

Enable GG

No

Unit

DISABLED=0 ENABLED=1

Breaker Hardware

156

Float

R/W

Breaker Close

Wait Time GG

Sec

0.1 - 600

Breaker Hardware

156

Float

R/W

Gen Open Pulse

Time GG

Sec

0.01 - 5

Breaker Hardware

156

Float

R/W

Gen Close Pulse

Time GG

Sec

0.01 - 5

Bus Condition Detection

(Gen Sensing)

158

Float

R/W

Dead Gen

Threshold GG

V

0 - 600000

Bus Condition Detection

(Gen Sensing)

158

Float

R/W

Dead Gen

Time Delay GG

Sec

0.1 - 600

Bus Condition Detection

(Gen Sensing)

158

Float

R/W

Gen Stable Over

VoltageP ickup GG

V

10 - 600000

Bus Condition Detection

(Gen Sensing)

158

Float

R/W

Gen Stable Over

Voltage Dropout GG

V

10 - 600000

Bus Condition Detection

(Gen Sensing)

158

Float

R/W

Gen Stable Under

Voltage Pickup GG

V

10 - 600000

Bus Condition Detection

(Gen Sensing)

158

Float

R/W

Gen Stable Under

Voltage Dropout GG

V

10 - 600000

Bus Condition Detection

(Gen Sensing)

158

Float

R/W

Gen Stable

Over Frequency

Pickup GG

Hz

46 - 64

Bus Condition Detection

(Gen Sensing)

158

Float

R/W

Gen Stable

Over Frequency

Dropout GG

Hz

46 - 64

Bus Condition Detection

(Gen Sensing)

158

Float

R/W

Gen Stable

Under Frequency

Pickup GG

Hz

46 - 64

Bus Condition Detection

(Gen Sensing)

158

Float

R/W

Gen Stable

Under Frequency

Dropout GG

Hz

46 - 64

Bus Condition Detection

(Gen Sensing)

158

Float

R/W

Gen Stable Activation

Delay GG

Sec

0.1 - 600

Bus Condition Detection

(Gen Sensing)

158

Float

R/W

Gen Failed Activation

Delay GG

Sec

0.1 - 600

This manual is related to the following products: