Basler Electric DECS-250N User Manual

Page 264

background image

248

9440500990 Rev D

PROFIBUS Communication

DECS-250N

Instance Name

Inst. #

Type

RW

Key Name

Unit

Range

Local Contact Inputs Cyclic

10

UINT8

R

CONTACTINPUTS INPUT4

Open=0, Closed=1

Local Contact Inputs Cyclic

10

UINT8

R

CONTACTINPUTS INPUT5

Open=0, Closed=1

Local Contact Inputs Cyclic

10

UINT8

R

CONTACTINPUTS INPUT6

Open=0, Closed=1

Local Contact Inputs Cyclic

10

UINT8

R

CONTACTINPUTS INPUT7

Open=0, Closed=1

Local Contact Inputs Cyclic

10

UINT8

R

CONTACTINPUTS INPUT8

Open=0, Closed=1

Local Contact Inputs Cyclic

10

UINT8

R

CONTACTINPUTS INPUT9

Open=0, Closed=1

Local Contact Inputs Cyclic

10

UINT8

R

CONTACTINPUTS INPUT10

Open=0, Closed=1

Local Contact Inputs Cyclic

10

UINT8

R

CONTACTINPUTS INPUT11

Open=0, Closed=1

Local Contact Inputs Cyclic

10

UINT8

R

CONTACTINPUTS INPUT12

Open=0, Closed=1

Local Contact Inputs Cyclic

10

UINT8

R

CONTACTINPUTS INPUT13

Open=0, Closed=1

Local Contact Inputs Cyclic

10

UINT8

R

CONTACTINPUTS INPUT14

Open=0, Closed=1

Local Contact Outputs
Cyclic

11

UINT8

R

CONTACTOUTPUTS
WATCHDOGOUTPUT

Open=0, Closed=1

Local Contact Outputs
Cyclic

11

UINT8

R

CONTACTOUTPUTS
OUTPUT1

Open=0, Closed=1

Local Contact Outputs
Cyclic

11

UINT8

R

CONTACTOUTPUTS
OUTPUT2

Open=0, Closed=1

Local Contact Outputs
Cyclic

11

UINT8

R

CONTACTOUTPUTS
OUTPUT3

Open=0, Closed=1

Local Contact Outputs
Cyclic

11

UINT8

R

CONTACTOUTPUTS
OUTPUT4

Open=0, Closed=1

Local Contact Outputs
Cyclic

11

UINT8

R

CONTACTOUTPUTS
OUTPUT5

Open=0, Closed=1

Local Contact Outputs
Cyclic

11

UINT8

R

CONTACTOUTPUTS
OUTPUT6

Open=0, Closed=1

Local Contact Outputs
Cyclic

11

UINT8

R

CONTACTOUTPUTS
OUTPUT7

Open=0, Closed=1

Local Contact Outputs
Cyclic

11

UINT8

R

CONTACTOUTPUTS
OUTPUT8

Open=0, Closed=1

Local Contact Outputs
Cyclic

11

UINT8

R

CONTACTOUTPUTS
OUTPUT9

Open=0, Closed=1

Local Contact Outputs
Cyclic

11

UINT8

R

CONTACTOUTPUTS
OUTPUT10

Open=0, Closed=1

Local Contact Outputs
Cyclic

11

UINT8

R

CONTACTOUTPUTS
OUTPUT11

Open=0, Closed=1

Settings Group Indication
Cyclic

12

UINT8

R

DECSCONTROL DECS
SOFT START
SELECT SECONDARY
SETTINGS

Primary settings active=0,
Secondary settings active=1

Settings Group Indication
Cyclic

12

UINT8

R

DECSCONTROL DECS PSS
SELECT
SECONDARY SETTINGS

Primary settings active=0,
Secondary settings active=1

Settings Group Indication
Cyclic

12

UINT8

R

DECSCONTROL DECS OEL
SELECT
SECONDARY SETTINGS

Primary settings active=0,
Secondary settings active=1

Settings Group Indication
Cyclic

12

UINT8

R

DECSCONTROL DECS UEL
SELECT
SECONDARY SETTINGS

Primary settings active=0,
Secondary settings active=1

Settings Group Indication
Cyclic

12

UINT8

R

DECSCONTROL DECS SCL
SELECT
SECONDARY SETTINGS

Primary settings active=0,
Secondary settings active=1

Settings Group Indication
Cyclic

12

UINT8

R

DECSCONTROL DECS
PROTECT
SELECT SECONDARY
SETTINGS

Primary settings active=0,
Secondary settings active=1

Settings Group Indication
Cyclic

12

UINT8

R

DECSCONTROL DECS PID
SELECT SECONDARY
SETTINGS

Primary settings active=0,
Secondary settings active=1

Settings Group Indication
Cyclic

12

UINT8

R

DECSCONTROL DECS VAR
LIMITER
SELECT SECONDARY
SETTINGS

Primary settings active=0,
Secondary settings active=1