Testing

DECS-250N

Graph Parameters

Any four of the following parameters may be selected for plotting in the graph areas.

Auxiliary voltage input (Vaux)

Average line current (Iavg)

Average line-to-line voltage (Vavg)

AVR error signal (Errln)

AVR output

Bus frequency (B Hz)

Bus voltage (Vbus)

Compensated frequency deviation
(CompF)

Control output (CntOp)

Cross-current input (Iaux)

Droop

FCR error

FCR state

FCR output

Field current (Ifd)

Field voltage (Vfd)

Filtered mechanical power (MechP)

Final PSS output (Pout)

Frequency response signal (Test)

FVR error

FVR state

FVR output

Generator frequency (G Hz)

Internal state (TrnOp)

Lead-lag #1 (x15)

Lead-lag #2 (x16)

Lead-lag #3 (x17)

Lead-lag #4 (x31)

Mechanical power (x10)

Mechanical power (x11)

Mechanical power (x7)

Mechanical power (x8)

Mechanical power (x9)

Negative sequence current (I2)

Negative sequence voltage (V2)

Network Load Share

Null Balance Level (Null Balance)

Null Balance State (Null State)

OEL controller output (OelOutput)

OEL reference

OEL state

Phase A current (Ia)

Phase A to B, line-to-line voltage (Vab)

Phase B current (Ib)

Phase B to C, line-to-line voltage (Vbc)

Phase C current (Ic)

Phase C to A, line-to-line voltage Vca

Position Indication (PositionInd)

Positive sequence current (I1)

Positive sequence voltage (V1)

Post-limit output (Post)

Power factor (PF)

Power HP #1 (x5)

Pre-limit output (Prelim)

PSS electrical power (PSSkW)

PSS terminal voltage (Vtmag)

Reactive power (kvar)

Real power (kW)

SCL controller output (SclOutput)

SCL reference

SCL state

SCL PF reference

Speed HP #1 (x2)

Synthesized speed (Synth)

Terminal frequency deviation (TermF)

Time response signal (Ptest)

Torsional filter #1 (Tflt1)

Torsional filter #2 (x29)

Total power (kVA)

UEL controller output (UelOutput)

UEL reference

UEL state

Var limiter output (VArLimOutput)

Var limiter reference

Var limiter state

Var/PF error

Var/PF state

Var/PF output

Washed out power (WashP)

Washed out speed (WashW)

Frequency Response

Frequency response testing functions are available by clicking the RTM Analysis screen Frequency
Response button. Frequency Response screen functions are illustrated in Figure 160 and described as
follows.

Test Mode

Frequency response testing may be performed in Manual or Auto mode. In Manual mode, a single
frequency can be specified to obtain the corresponding magnitude and phase responses. In Auto mode,