Basler Electric DECS-250N User Manual
Page 273

9440500990 Rev D
257
DECS-250N
PROFIBUS Communication
Instance Name
Inst. #
Type
RW
Key Name
Unit
Range
CEM Output Status
41
UINT8
R
CEM OUTPUT 2
Open=0, Closed=1
CEM Output Status
41
UINT8
R
CEM OUTPUT 3
Open=0, Closed=1
CEM Output Status
41
UINT8
R
CEM OUTPUT 4
Open=0, Closed=1
CEM Output Status
41
UINT8
R
CEM OUTPUT 5
Open=0, Closed=1
CEM Output Status
41
UINT8
R
CEM OUTPUT 6
Open=0, Closed=1
CEM Output Status
41
UINT8
R
CEM OUTPUT 7
Open=0, Closed=1
CEM Output Status
41
UINT8
R
CEM OUTPUT 8
Open=0, Closed=1
CEM Output Status
41
UINT8
R
CEM OUTPUT 9
Open=0, Closed=1
CEM Output Status
41
UINT8
R
CEM OUTPUT 10
Open=0, Closed=1
CEM Output Status
41
UINT8
R
CEM OUTPUT 11
Open=0, Closed=1
CEM Output Status
41
UINT8
R
CEM OUTPUT 12
Open=0, Closed=1
CEM Output Status
41
UINT8
R
CEM OUTPUT 13
Open=0, Closed=1
CEM Output Status
41
UINT8
R
CEM OUTPUT 14
Open=0, Closed=1
CEM Output Status
41
UINT8
R
CEM OUTPUT 15
Open=0, Closed=1
CEM Output Status
41
UINT8
R
CEM OUTPUT 16
Open=0, Closed=1
CEM Output Status
41
UINT8
R
CEM OUTPUT 17
Open=0, Closed=1
CEM Output Status
41
UINT8
R
CEM OUTPUT 18
Open=0, Closed=1
CEM Output Status
41
UINT8
R
CEM OUTPUT 19
Open=0, Closed=1
CEM Output Status
41
UINT8
R
CEM OUTPUT 20
Open=0, Closed=1
CEM Output Status
41
UINT8
R
CEM OUTPUT 21
Open=0, Closed=1
CEM Output Status
41
UINT8
R
CEM OUTPUT 22
Open=0, Closed=1
CEM Output Status
41
UINT8
R
CEM OUTPUT 23
Open=0, Closed=1
CEM Output Status
41
UINT8
R
CEM OUTPUT 24
Open=0, Closed=1
AEM Analog Output Meter
42
Float
R
AnalogOutput1RawValue GG
No Unit
0 – 10 V or 4 – 20 mA
AEM Analog Output Meter
42
Float
R
AnalogOutput2RawValue GG
No Unit
0 – 10 V or 4 – 20 mA
AEM Analog Output Meter
42
Float
R
AnalogOutput3RawValue GG
No Unit
0 – 10 V or 4 – 20 mA
AEM Analog Output Meter
42
Float
R
AnalogOutput4RawValue GG
No Unit
0 – 10 V or 4 – 20 mA
AEM Analog Output Meter
42
Float
R
AnalogOutput1ScaledValue
GG
No Unit
n/a
AEM Analog Output Meter
42
Float
R
AnalogOutput2ScaledValue
GG
No Unit
n/a
AEM Analog Output Meter
42
Float
R
AnalogOutput3ScaledValue
GG
No Unit
n/a
AEM Analog Output Meter
42
Float
R
AnalogOutput4ScaledValue
GG
No Unit
n/a
AEM Analog Output Status
43
UINT8
R
REMOTEANALOGOUTPUT1
OUT OF RANGE
Value in range=0, Value out of
range=1
AEM Analog Output Status
43
UINT8
R
REMOTEANALOGOUTPUT2
OUT OF RANGE
Value in range=0, Value out of
range=1
AEM Analog Output Status
43
UINT8
R
REMOTEANALOGOUTPUT3
OUT OF RANGE
Value in range=0, Value out of
range=1
AEM Analog Output Status
43
UINT8
R
REMOTEANALOGOUTPUT4
OUT OF RANGE
Value in range=0, Value out of
range=1
Config. Prot. Status
44
UINT8
R
CONFIGPROT1
CONFPROTTHRESH1TRIP
Not tripped=0, Tripped=1
Config. Prot. Status
44
UINT8
R
CONFIGPROT1
CONFPROTTHRESH2TRIP
Not tripped=0, Tripped=1
Config. Prot. Status
44
UINT8
R
CONFIGPROT1
CONFPROTTHRESH3TRIP
Not tripped=0, Tripped=1
Config. Prot. Status
44
UINT8
R
CONFIGPROT1
CONFPROTTHRESH4TRIP
Not tripped=0, Tripped=1
Config. Prot. Status
44
UINT8
R
CONFIGPROT2
CONFPROTTHRESH1TRIP
Not tripped=0, Tripped=1
Config. Prot. Status
44
UINT8
R
CONFIGPROT2
CONFPROTTHRESH2TRIP
Not tripped=0, Tripped=1