beautypg.com

4 stirrer, 5 further information, 4 stirrer 29.11.5 further information – Metrohm 900 Touch Control Manual User Manual

Page 419

background image

■■■■■■■■■■■■■■■■■■■■■■

29 Parameters

900 Touch Control

■■■■■■■■

403

29.11.4 Stirrer

The parameters for the stirrer are edited under [Stirrer].

Stirrer

Selection of the MSB connector the stirrer is connected to. Every MSB
connector will always be displayed.

Selection

1 | 2 | 3 | 4

Default value

1

Stirring rate

Setting the stirring rate. It can be set in steps of –15 to +15. The default
setting 8 corresponds to 1000 rpm. The formula for calculating the rota-
tional speed is specified in chapter 32.3, page 489. The optimum stirring
rate can be tested in the manual control.

The algebraic sign of the stirring rate changes the direction in which the
stirring is done. When the stirrer is viewed from above, this means:

"+": counterclockwise rotation

"–": clockwise rotation

Input range

–15 - 15

Default value

8

29.11.5 Further information

Table 15

Limit values of the three electrode types

Rating

Excellent electrode

Good electrode

Usable electrode

Electrode type "Standard"

Streaming potential

2.5 mV

3.0 mV

4.0 mV

Drift

2.0 mV/s

2.5 mV/s

3.0 mV/s

Min. slope

96.5 %

96.0 %

95.0 %

Max. slope

101.0 %

102.0 %

103.0 %

Response time

45 s

50 s

60 s

Lower limit Uoff

–15 mV

Upper limit Uoff

15 mV

Electrode type "Gel"

Streaming potential

3.0 mV

3.5 mV

4.5 mV

Drift

2.5 mV/s

3.0 mV/s

4.0 mV/s

Min. slope

96.5 %

96.0 %

95.0 %