Operation Manual – HWPing
H3C S3100-52P Ethernet Switch
Chapter 1 HWPing Configuration
1-3
Operation
Command
Description
Configure the automatic
test interval.
frequency
interval
Optional
By default, the automatic
test interval is zero,
indicating no automatic
test will be performed.
Configure the timeout
time of the test.
timeout
time
Optional
By default, the timeout
time is 3 seconds.
Execute the test
test-enable
Required
1.2.3 Displaying HWPing Configuration
After the above HWPing configuration, you can execute the display command in any
view to display the information of HWPing test operation status to you can verify the
configuration effect.
Table 1-2
Display HWPing configuration
Operation
Command
Description
Display the information of
HWPing test history
display hwping history
[
administrator-name
operation-tag
]
Display the latest HWPing
test results
display hwping results
[
administrator-name
operation-tag
]
The display command
can be executed in any
view.
1.2.4 Configuration Example
I. Network requirement
Perform an HWPing ICMP test between two switches. Like a ping test, this test uses
ICMP to test the RTTs of data packets between the source and the destination.
II. Configuration procedure
# Enable HWPing Client.
System View: return to User View with Ctrl+Z.
[H3C] hwping-agent enable
# Create an HWPing test group “administrator icmp”.
[H3C] hwping administrator icmp
# Specify the test type as ICMP.