H3C Technologies H3C S3100 Series Switches User Manual
Page 162

Operation Manual – DLDP
H3C S3100-52P Ethernet Switch
Chapter 1 DLDP Configuration
1-8
Operation
Command
Description
Set the DLDP operating mode
dldp work-mode
{ enhance
| normal }
Optional.
By default,
DLDP works in
normal mode
and does not
detect
unidirectional
links.
Enter Ethernet port view
interface
interface-type
interface-number
—
Force the duplex attribute
duplex full
Required
Force the speed value
speed
speed-value
Required
Display the configuration
information about the
DLDP-enabled port
display dldp
{ unit-id |
interface-type
interface-number
}
You can
execute this
command in
any view.
Note:
z
When you use the dldp enable/dldp disable command in system view to
enable/disable DLDP on all optical ports of the switch, the configuration takes effect
on the existing optical ports, instead of those added subsequently.
z
DLDP can operate normally only when the same authentication mode and
password are set on the local and peer ports.
z
When the DLDP protocol works in the normal mode, the system can identify only
one type of unidirectional link caused by fiber cross-connection.
z
When the DLDP protocol works in enhanced mode, the system can identify two
types of unidirectional links: one is caused by fiber cross-connection and the other is
caused by one fiber being not connected or being broken.
z
When the device is busy with services and the CPU utilization is high, DLDP may
issue mistaken reports. You are recommended to configure the operating mode of
DLDP as manual after unidirectional links are detected, so as to reduce the
influence of mistaken reports.