1.5.3 Configuring BPDU Protection
I. Configuration procedure
Table 1-30
Configure BPDU protection
Operation
Command
Description
Enter system view
system-view
—
Enable the BPDU
protection function
stp
bpdu-protection
Required
The BPDU protection function
is disabled by default.
II. Configuration example
# Enable the BPDU protection function.
[H3C] stp bpdu-protection
Caution:
As Gigabit ports of an S3100-52P Ethernet switch cannot be shut down, the BPDU
protection function is not applicable to these ports even if you enable the BPDU
protection function and specify these ports to be MSTP edge ports.
1.5.4 Configuring Root Protection
I. Configuration procedure
Table 1-31
Configure the root protection function in system view
Operation
Command
Description
Enter system view
system-view
—
Enable the root protection
function on specified
ports
stp interface
interface-list
root-protection
Required
The root protection function
is disabled by default.