beautypg.com

3 configuring bpdu protection, I. configuration procedure, Ii. configuration example – H3C Technologies H3C S3100 Series Switches User Manual

Page 211: 4 configuring root protection

background image

Operation Manual – MSTP
H3C S3100-52P Ethernet Switch

Chapter 1 MSTP Configuration

1-36

1.5.3 Configuring BPDU Protection

I. Configuration procedure

Table 1-30

Configure BPDU protection

Operation

Command

Description

Enter system view

system-view

Enable the BPDU
protection function

stp
bpdu-protection

Required
The BPDU protection function
is disabled by default.

II. Configuration example

# Enable the BPDU protection function.

system-view

[H3C] stp bpdu-protection

Caution:

As Gigabit ports of an S3100-52P Ethernet switch cannot be shut down, the BPDU
protection function is not applicable to these ports even if you enable the BPDU
protection function and specify these ports to be MSTP edge ports.

1.5.4 Configuring Root Protection

I. Configuration procedure

Table 1-31

Configure the root protection function in system view

Operation

Command

Description

Enter system view

system-view

Enable the root protection
function on specified
ports

stp interface

interface-list

root-protection

Required
The root protection function
is disabled by default.