Operation Manual – Information Center

H3C S3100-52P Ethernet Switch

Chapter 1 Information Center

1-18

Note:

Note the following items when you edit file “/etc/syslog.conf”.

z

A note must start in a new line, starting with a “#" sign.

z

In each pair, a tab should be used as a separator instead of a space.

z

No space is permitted at the end of the file name.

z

The facility and received log information severity specified in file “/etc/syslog.conf”
must be the same with those corresponding parameters configured in commands
info-center loghost

and info-center source. Otherwise, log information may not

be output to the log host normally.


Step 3: After the log file “information” is created and the file “/etc/syslog.conf” is
modified, execute the following commands to view the process ID of the system
daemon “syslogd”, stop the process, and then restart the daemon "syslogd" in the
background with the “-r” option.

# ps -ae | grep syslogd

147

# kill -9 147

# syslogd -r &

Note:

In case of Linux log host, the daemon “syslogd” must be started with the “-r” option.


After all the above operations, the switch can record information in the corresponding
log file.

Note:

Through combined configuration of the device name (facility), information severity level
threshold (severity), module name (filter) and the file “syslog.conf”, you can sort
information precisely for filtering.

1.4.3 Log Output to the Console

I. Network requirements

The switch sends the following information to the console: the log information of the two
modules ARP and IP, with severity higher than “informational”.