II. Network diagram

H3C 1

S3100-52P

1.0.

1.0.1.11/24

1.12/24

H3C 1

S3100-52P

1.0.

1.0.1.11/24

1.12/24

n

Figure 1-6

Network diagram for the NTP server mode configuratio

III. Configuration procedure

Perform the following configurations on the S3100-52P switch.
# View the NTP status of the S3100-52P switch before synchronization.

display ntp-service status

Clock status: unsynchronized

Clock stratum: 16

Reference clock ID: none

Nominal frequence: 99.8562 Hz

Actual frequence: 99.8562 Hz

Clock precision: 2^7

Clock offset: 0.0000 ms

Root delay: 0.00 ms

Root dispersion: 0.00 ms

Peer dispersion: 0.00 ms

Reference time: 00:00:00.000 UTC Jan 1 1900 (00000000.00000000)

# Set H3C1 to the NTP server of the S3100-52P switch.

system-view

[S3100-52P] ntp-service unicast-server 1.0.1.11

# (After the above configurations, the S3100-52P switch is synchronized to H3C1.)
View the NTP status of the S3100-52P switch.

[S3100-52P] display ntp-service status

Clock status: synchronized

Clock stratum: 3

Reference clock ID: 1.0.1.11