2.1.3 Setting the System Name of the Switch

Table 2-3

Set the system name of the switch

Operation

Command

Description

Enter system view

system-view

Set the system

name of the switch

sysname

sysname

Optional
By default, the name is H3C.

2.1.4 Setting the Date and Time of the System

Table 2-4

Set the date and time of the system

Operation

Command

Description

Set the current date

and time of the

system

clock datetime
HH:MM:SS
YYYY/MM/DD

Optional
By default, it is 23:55:00 04/01/2000

when the system starts up.

2.1.5 Setting the Local Time Zone

This configuration task is to set the name of the local time zone and the difference
between the local time zone and the standard UTC (universal time coordinated) time.

Table 2-5

Set the local time zone

Operation

Command

Description

Set the local time

zone

clock timezone

zone-name { add |

minus

} HH:MM:SS

Optional
By default, it is the

UTC time zone.

2.1.6 Setting the Summer Time

This configuration task is to set the name, time range (start time and end time), and
time offset of the summer timer. The operation here saves you from manually adjust the
system time.

z

When the system reaches the specified start time, it automatically adds the
specified offset to the current time, so as to toggle the system time to the summer
time.

z

When the system reaches the specified end time, it automatically subtracts the
specified offset from the current time, so as to toggle the summer time to normal
system time.