H3C Technologies H3C S3100 Series Switches User Manual
Page 44

Operation Manual – Login
H3C S3100-52P Ethernet Switch
Chapter 2 Logging in through the Console Port
2-10
Operation
Command
Description
Set the
baud rate
speed
speed-value
Optional
The default baud rate of an AUX
port (also the Console port) is
9,600 bps.
Set the
check
mode
parity
{ even | none
| odd }
Optional
By default, the check mode of a
Console port is set to none, that
is, no check bit.
Set the
stop bits
stopbits
{ 1 | 1.5 |
2
}
Optional
The default stop bits of a Console
port is 1.
Configure
the
Console
port
Set the
data bits
databits
{ 7 | 8 }
Optional
The default data bits of a Console
port is 8.
Configure the command
level available to users
logging into the user
interface
user privilege level
level
Optional
By default, commands of level 3
are available to users logging into
the AUX user interface.
Make terminal services
available to the user
interface
shell
Optional
By default, terminal services are
available in all user interfaces.
Set the maximum
number of lines the
screen can contain
screen-length
screen-length
Optional
By default, the screen can contain
up to 24 lines.
You can use the screen-length 0
command to disable the function
to display information in pages.
Set history command
buffer size
history-command
max-size
value
Optional
The default history command
buffer size is 10. That is, a history
command buffer can store up to
10 commands by default.
Set the timeout time for
the user interface
idle-timeout
minutes
[ seconds ]
Optional
The default timeout time of a user
interface is 10 minutes.
With the timeout time being 10
minutes, the connection to a user
interface is terminated if no
operation is performed in the user
interface within 10 minutes.
You can use the idle-timeout 0
command to disable the timeout