Establish a static channel connection, Establish a static channel connection -8 – Carrier Access Network Device Axxius 800 User Manual
Page 80

4-8
Axxius 800 - Release 2.2
Configuration
Basic System Setup
Establish a Static Channel Connection
Use the following commands to establish a static channel connection.
Command
Description
set {ds3-addr} protect
{off|on}
Set port protection on the DS3.
set {ds3-addr} reversion
{off|on}
Set protection reversion on the DS3.
set {ds1-addr} threshold
{day|min15} {ccv|ces|cses|lcv
|les|pcv|pes|pses|sefs|uas)
Set default thresholds for a DS3.
set {ds3-addr} unit
{"string"}
Set the DS3 unit code PMDL string.
Command
Description
set {ds0-addr} type
{voice|data}
Set the channel type for the channel you
want to map. See set (ds0) command for
details.
set {ds0-addr} signal {emdw|
emi|emicpd|emw|gs|ls}
Set the signaling option for the channel you
want to map. See set (ds0) command for
details.
connect {slot:port}
{slot:port}
Connect the channels. See the show connect
command for details.