Alarms, Alarms -11 – Carrier Access Network Device Axxius 800 User Manual
Page 411
Axxius 800 - Release 2.2
10-11
OCU-DP Card
Alarms
Alarms
The OCU-DP cards and supporting Controller Software will support the following
alarms:
Alarm/
Event
Severity
Category
Description
Clear Mechanism
(alarms only)
Card
Detect
Information
Equipment
OCU-DP card inserted
Card
Removed
Information
Equipment
OCU-DP card removed
Out of
Service
(OOS)
Major
Facility
Network sending Out-of-
Service code (OOS) or
card has LOS.
Correct with Network or
replace or deprovision the
card.
Los of
Signal
(LOS)
Major
Facility
No signal at customer link.
Correct with Customer
data path, replace the card,
or reconnect the drop.
Los of
Frame
(LOF)
Major
Facility
Framing patter not
detected at customer link.
Correct with Customer
data path, replace the card,
or reconnect the drop.
Bipolar
Violation
(BPV)
Minor
Facility
Excessive violations on
customer interface.
Correct with the incoming
signal, or deprovision card.