Show autoexit, Show (bri), Show autoexit -177 – Carrier Access Network Device Axxius 800 User Manual
Page 277: Show (bri) -177

Axxius 800 - Release 2.2
5-177
CLI Commands
show
show autoexit
Use the show autoexit command to display whether autoexit is on or off. If on, the time-out
period is displayed.
Syntax:
show autoexit
Example:
> show autoexit
Autoexit is off.
show (bri)
Use the show (bri) command to display settings for BRIs.
Syntax:
show {bri-addr}
Example:
> show 5:1
The example will display the settings for port 1 (BRI) on slot 5.
SLOT 5:
Settings for BRI Port 1:
Mode: LT3DS0
Up/Down: UP
CRV: 0
Performance Sync Source: AXXIUS
Auto Activate: OFF
Performance Threshold Settings 1 hour 1 day
------ ------
errored seconds: 40 100
severely errored seconds: 10 25
{bri-addr}
The BRI address is in the form {slot|slot:port}. Where {slot} displays information for all
ports on the card, {slot:port} for only the defined port.
slot
Slot number (1-8) where the BRI card is located
port
Port number, range or all.