Service interfaces supported, Network standards, Clocking – Carrier Access Network Device Axxius 800 User Manual

Page 377: Alarms, Clocking -5 alarms -5

background image

Axxius 800 - Release 2.2

7-5

DS3

Controller

Card

Technical Specifications

Service Interfaces Supported

l

Dual V.35/.54 Service card (hardened)

l

FXO Voice Service card

l

ISDN BRI Service card

l

OCU-DP Service card

l

Quad DS1 ADPCM Service card (hardened)

l

Quad T1 Service card (hardened)

l

Single Channel POTS Service card (hardened)

l

Single Channel POTS with Modem Service card

l

Terminal Server Router (TSR) card (hardened)

Network Standards

l

ANSI T1-403 and T1.404

Clocking

l

Loop-timed from any DS1 within the DS3

l

External BITS clock

l

Revertive or non-revertive (provisionable) clock switching provides automatic
backup to secondary DS3 should the primary DS3 fail

l

Operates as a Stratum 4E device as defined by Telcordia GR-1244-CORE and
AT&T TR 62411

Alarms

l

Three visible alarm outputs, critical, major and minor

l

Three audible alarm outputs, critical, major and minor

l

Alarm Cut-Off for audible alarm outputs

l

Ten alarm inputs

l

Alarm contacts accessible from external alarm connector

l

All alarms are logged in an event log

l

Loss of power triggers minor alarm

l

Generates SNMP traps for alarming (MIB objects)