Set clock (1 and 2), Set date, Set clock (1 and 2) -75 – Carrier Access Network Device Axxius 800 User Manual
Page 175: Set date -75, Set date comman

Axxius 800 - Release 2.2
5-75
CLI Commands
set
set clock (1 and 2)
Use the set clock (1 and 2) command to set the master transmit clock. The primary master clock
source may be used to clock each DS1 transmitter. The clock circuit automatically switches to
the secondary clock source if the primary clock fails.
Syntax:
set {clock1|clock2} {source}
Example:
set clock1 a:1
To set the primary master clock source to A:1.
Example:
set clock2 1:2
Set the secondary master clock source to Quad T1 in slot 1 source selected.
{clock1}
Set primary master transmit clock source.
{clock2}
Set secondary master transmit clock source.
{source}
Set the clock source to one of the following:
NOTE:
To set DS3 clocking see set (ds3) clock command.
set date
Use the set date command to set the date.
Syntax:
set date {mm/dd/yyyy}
Example:
set date 1/1/2002
The example will set the date to January 1, 2002.
{mm/dd/yyyy}
bits1_t1
Select BITS1 T1
bits2_t1
Select BITS2 T1
bri-addr
Clock recovered from the BRI port on the BRI card (BRI card must be in
LUNT and 3DS0 mode)
ds1-addr
Clock recovered from the DS1 receiver
internal
Internal stratum 4E oscillator
mm
Represents the month. Range is 1-12, single digits can be entered.
dd
Represents the Day. Range is 1-31, single digits can be entered.
yyyy
Represents the year. Range is 1999-2106.