Loopback

Tests

Overview

Overview

A loopback test is a diagnostic procedure in which a signal is transmitted and returned
to the sending device after passing through all or a portion of a network or circuit. The
returned signal is compared with the transmitted signal in order to evaluate the integrity
of the equipment or transmission path.

DS1 Loopbacks

Note: T1 LEDs flash green during any DS1 loopback.

DS1 Line Loop

Loops at DS1 (at framer), signal not reframed. Have DS1 vendor check for framing/
errors.

Enable Line Loopback

> set a:1 line loopup

OK

T1

Axxius

Local

DTE

Local

DCE

V.35

DS1

Network

Loops DS1 as shown