set
set (router) port type
Use the set (router) port type command to set the application being used for a RS-232
(serial) port. This setting can be issued when the card is physically strapped for Ethernet,
but has no effect. This command applies to the TSR only.
Syntax:
set {tsr_card-addr} port {port-number} type
{termserv|rawtcp|tbos}
Example:
set 5 port 2 type tbos
{tsr_card-addr} -
The slot number (1-8) that contains the TSR card.
{port-number} -
The port number (1-4) of the TSR card.
{termserv|rawtcp|tbos}
termserv
Terminal server. Default.
rawtcp
Raw TCP.
tbos
TBOS (Telemetry Byte Oriented Serial). Note: this setting
requires TBOS feature to be enabled on the TSR service card.
Contact Customer Service for information on purchasing this
software keyed feature.