10-6
Axxius 800 - Release 2.2
OCU-DP Card
Technical Specifications
Network Interface
l
Each OCU port DS0 cross-connected to T1 port
Loopbacks
OCU, CSU and DSU:
l
Manual loopbacks activate via CLI
l
Non-latching loopbacks activate via network code
l
Latching loopbacks activate via network code
Clocking
l
Loop-timed from any T1 in the platform
l
Sources clock to the DTE device
Power Consumption
l
6 W maximum, Quad-Port OCU-DP card
l
3 W maximum, Single-Port OCU-DP card
Environment
In addition to the systems environment requirements, the following applies to the
OCU-DP card. For additional information see Installation Environment on page 2-3.
l
Operating temperature range: 32
°
to 104
°
F (0
°
to 40
°
C)
Physical
l
Dimensions: 3.5 in. (H) x 0.75 in. (W) x 11.25 in. (D)
8.9 cm (H) x 1.9 cm (W) x 28.6 cm (D)
l