Axxius 800 - Release 2.2

14-5

Quad T1 & Quad DS1/E1 Card

Technical Specifications

Clocking

l

Loop-timed from any T1

l

External from BITS clock input (t1.101, t1.102 signal type)

l

Revertive or non-revertive (provisionable clock switching provides automatic
backup to secondary T1 should the primary T1 fail

l

Operates as a Stratum 4E device as defined by Telcordia GR-1244-CORE and
AT&T TR 62411

Alarms

l

Support standard T1.403 alarms

l

LOS (Loss of Signal), Red, Yellow, Blue

l

ESF Performance Error Count Threshold

l

Timing Loss

l

All alarms are logged in an event log

l

Loss of power triggers minor alarm

l

Generates SNMP traps for alarming

Testing and Diagnostics

l

T1.403 payload loopbacks (ESF only)

l

T1.403 remote and local line loopbacks (ESF and SF)

l

T1.231 Performance History (15 minute intervals, 24 hour totals)

l

T1.403 Performance Report Messages (PRMs)

Power Consumption

l

Less than 4.5 W per card