1 general data and operating conditions, 2 supported protocols, General data and operating conditions – Lenze E94ARNE Regenerative power supply User Manual
Page 99: Supported protocols
EDS94ARNExxxx EN 2.3 - 06/2014
L
99
9400 regenerative power supply module | Parameter setting
"CAN on board" system bus
General information
6.1.1
General data and operating conditions
6.1.2
Supported protocols
Area
Values
Communication profile
CANopen (DS301 V4.02)
Communication medium
DIN ISO 11898
Network topology
Line terminated at both ends (e.g. by means of Sub-D plug, type EWZ0046)
Adjustable node addresses
1 ... 127
• Adjustable via DIP switch on the memory module or via code
.
Max. number of nodes
127
Baud rate
10, 20, 50, 125, 250, 500, 800, 1000 kbps or automatic detection
• Adjustable via DIP switch on the memory module (exception: MM1xx
memory module) or via code
Process data
• Max. 4 TPDOs with 1 ... 8 bytes
• Max. 4 RPDOs with 1 ... 8 bytes
Parameter data
Max. 10 client and server SDO channels with 1 ... 8 bytes
TPDO transmission mode
• At change of data
• Time-controlled 1 ... x ms
• After 1 ... 240 received sync telegrams
Category
Protocol
Standard PDO protocols
PDO write
PDO read
SDO protocols
SDO download
SDO download initiate
SDO download segment
SDO upload
SDO upload initiate
SDO upload segment
SDO abort transfer
SDO block download
SDO block download initiate
SDO block download end
SDO block upload
SDO block upload initiate
SDO block upload end
NMT protocols
Start remote node (master and slave)
Stop remote node (slave)
Enter pre-operational (slave)
Reset node (slave and local device)
Reset communication (slave)
Monitoring protocols
Node guarding (master and slave)
Heartbeat (heartbeat producer and heartbeat consumer)