2 selecting the recording time/sample rate, Selecting the recording time/sample rate – Lenze E94ARNE Regenerative power supply User Manual
Page 176
9400 regenerative power supply module | Parameter setting
Oscilloscope
Operation
176
L
EDS94ARNExxxx EN 2.3 - 06/2014
How to delete a selection:
1. Go to the Vertical group box and double-click the variable to be removed in the
Variable column.
2. Click Delete channel in the Select variable dialog box.
• The dialog box is closed and the selection is deleted.
7.4.2
Selecting the recording time/sample rate
How to select the recording time and the sample rate:
1. Go to the Horizontal group box and select the desired time base from the Time
base list field.
• The current time base setting multiplied by ten results in the recording time.
• Since the measured data memory of the regenerative power supply module has
a limited capacity, a compromise must be found between the sample rate and
the recording time.
2. Enter the desired sample rate in [ms] in the Sample rate input field of the Recording
group box.
• Clicking the
button to the right of the Sample rate input field opens the
Sample rate dialog box where you can additionally select the Increased sample
rate option:
Note!
Due to system-inherent reasons, only integer multiples of 1/(sample rate in ms)
are recorded when the Increased sample rate option has been selected.
• As a complete representation in the oscillograph requires (10 * 1/(sample rate
in ms)) + 1 measured values, the last measured value is always lacking and
the represented curve ends at the second to last measured value.
• The recorded curve is not expanded or compressed.