5 save selected application, Save selected application – Lenze E94ARNE Regenerative power supply User Manual
Page 43

EDS94ARNExxxx EN 2.3 - 06/2014
L
43
9400 regenerative power supply module | Parameter setting
Device interface
Device commands
4.1.5
Save selected application
After mains switching, the regenerative power supply module always loads the default
start application from the memory module, even if a different application has been active
before.
The device command
= "7: Save selected application" can be used to define the
active application as start application.
[4-4]
"Save selected application" function
When this device command is executed, the parameter set is also saved automatically.
The number of the currently active application is displayed in
Possible status displays for this device command
Related device commands
* In this example the active application 2 is defined as start application
PS
9400
RAM
Firmware
Application 2*
PS
Application 3
Memory module MM
Application 1
Application 2*
PS
Status (
Meaning
492802 Device command in process
458752 Device command executed successfully
458753 General fault